Revision: 0
FlexxPump1 B
User Manual
12
EN-
3.4
Technical data
Housing
Dimensions without cartridge
width x height x
depth
83 x 82 x 85
mm
Dimensions with catridge
83 x 149 x 85
Weight (without cartridge)
appx.
350
g
Mounting options
backside: female thread M5 (2x)
bottom: female thread M5 (1x)
bottom: male thread M16 (1x)
max. torque mounting
3
Nm
Mounting position
any, upright (preffered)
Material housing
PA 6.6 GF30 / POM
Material outlet
stainless steel
Operating temperature
-15 ... +60*
°C
Lubricant and hydraulic
Volume cartridge
125
ml
Lubricant characteristics
grease until NLGI class 2
Number of outlets
1
Hydraulic connection
directly or via PA-tube
Number of lubrication points
up to 8 in conjunction with aluminum progressi-
ve distributor**
max. pressure
35
bar
Grease delivery
per stroke
0.16 (-5%)
cm³
Electrics
Display
LCD
Operating voltage
4.5
V
Protection
-
A
Protection class
IP 54
* Only valid when using the lithium battery. When the alkaline battery is used, the permissible
operating temperature for the FP1 B is +15°C ... +60°C is limited. Please note, however, that in
individual cases the operating temperature may depend on other factors (e.g. lubricant).
** The stated value depends on the specific application and may vary considerably in individual
cases depending on the lubricant used and other conditions.