EN

-

The battery can be changed during normal operation of the FP4 BXXX-EXT.

FP4 BXXX-EXT shows Error E3; the red LED flashes every 5 seconds.

In the following steps is described how you change the battery.

1. Loosen the screws and remove the cover 

to open the battery compartment.

 Turn the four screws counterclockwise. 

 Once the screws are loosened, the cover 

can be removed. 

 Remove the cover from the battery com-

partment.

 Store the cover next to you.

2. Remove empty battery pack.

 Pull the empty battery pack or battery 

holder out of the battery compartment with 

the battery cable.

 If using the battery pack, disconnect the 

reverse polarity protected plug connection 

and dispose of the empty battery pack pro-

perly after completing the work.

 When using your own batteries, remove 

them from the battery holder.

Summary of Contents for 214574

Page 1: ...ary sheet s in the original user manual remain valid without exception Further supplementary sheets to the original instruction manual are valid in addition to this supplementary sheet This document i...

Page 2: ...e LCD on the front panel displays the various operating states further information empty cartridge error can be read The present FlexxPump4 as battery version has no electrical interface The supplied...

Page 3: ...tment for battery pack or battery holder 8 Nameplate with designation CE mark and serial number 9 Through hole for assembly on both sides Fig 1 Overview FP4 BXXX EXT The FP4 BXXX EXT is available in s...

Page 4: ...EXT Supplementary Sheet Revision 1 04 EN 3 4 Technical data Electrics Battery sizes alkaline or lithium TriboServ standard battery pack 6V 4x R6 with 1 5V or 4x R14 with 1 5V primary cells or recharg...

Page 5: ...ondition as delivered The FP4 BXXX EXT is delivered in a card board box Depending on the version orde red additional accessories such as a battery pack or lubricant cartridge are included 2 Mechanical...

Page 6: ...let Pay attention to cleanliness when performing the work Be sure to avoid dirt liquids and foreign objects from entering the cartridge 3 Remove the housing from the power unit of the FP4 BXXX EXT Tur...

Page 7: ...osition is reached after two full rotations when the label of the lubricant cartridge is aligned with the front of the FP4 BXXX EXT 5 Mount the upper housing from the pump unit of the FP4 BXXX EXT Pla...

Page 8: ...attery packs Connect the new battery to the battery cable via the reverse polarity protected plug or insert new batteries into the matching battery holder and connect it to the reverse polarity protec...

Page 9: ...se original lubricant cartridges with lubricant approved by the manufacturer Observe the maximum storability of the lubricant filled in car tridges NOTICE It is not possible to refill empty or opened...

Page 10: ...ricant cartridge Losen the retaining ring at the marked positions 2 Remove the empty cartridge Turn the lubricant cartridge counterclock wise from the FP4 B and dispose of it Pay attention to cleanlin...

Page 11: ...LED which flashes every 5 seconds A separate ack nowledgement is not required The green LED flashes briefly every 60 seconds After completion of this work the FP4 B automatically returns to the last...

Page 12: ...ment Turn the four screws counterclockwise Once the screws are loosened the cover can be removed Remove the cover from the battery com partment Store the cover next to you 2 Remove empty battery pack...

Page 13: ...e plug does not protrude from the battery compartment and become trapped when the cover is screwed on Carry out the work according to the above description If an error was displayed in the LCD before...

Page 14: ...115 10 5 1 72 kg Alle Schlauchanschlussteile f r Schlauch 6mm All tube connection parts for tube 6mm Benennung Name Art Nr Item No Farbe Colors Schmierstoff Lubricant FlexxPump4 B412 EXT 214580 gr n g...

Reviews: