TriboServ 210948 Supplementary Sheet Download Page 10

revision: 0

FlexxPump4 DXXX-OIL

Supplementary Sheet

10

EN-

9.2 

Oil Refilling

1. Remove the housing from the power unit

of the FP4 DXXX-OIL.

 Separate the housing from the power unit

by turning the retaining ring counterclock-

wise.

 Make sure that no dirt, water or foreign

bodies enters the lubricant inlet.

 Alternatively, you can remove the acti-

vation and programming key on the upper 

housing of the FP4 DXXX-OIL to expose 

the oil reservoir. Turn the action pin to the 

OPEN position and pull it off.

2. Filling the oil cartridge

 Fill the cartridge with oil until the mark 

"max. level" on the oil cartridge is reached

 Pay attention to cleanliness when

carrying out the work. It is imperative that

dirt and foreign bodies do not enter the

cartridge.

3. Assembling the housing on the power unit

of the FP4 DXXX-OIL.

 Place the dismantled housing on the FP4

DXXX-OIL and press it onto the power unit.

 Fasten the housing to the power unit by

turning the retaining ring clockwise.

 The retaining ring must snap into place

when turning and be completely tightened.

 

If you have only removed the activation 

and programming key to fill the oil cartridge, 

remount it in the upper housing of the FP4 

DXXX-OIL. Note the CLOSE position.

Summary of Contents for 210948

Page 1: ...on FlexxPump4 Direct FP4 D Product revision Chapters not replaced by this supplementary sheet s in the original user manual remain valid without exception Further supplementary sheets to the original...

Page 2: ...xPump4 as DXXX OIL version has to be integrated into an external control e g PLC The FP4 DXXX OIL has an electrical interface with which you can control and command the FP4 D Furthermore the FP4 DXXX...

Page 3: ...OIL 1 Lubricant outlet outlets different versions possible 2 Retaining ring 3 Housing 4 M12x1 electrical interface 5 Nameplate with designation CE mark and serial number 6 Through hole for assembly 7...

Page 4: ...revision 0 FlexxPump4 DXXX OIL Supplementary Sheet 04 EN 3 4 Technical data Lubricants and hydraulics Volume Cartridge 250 400 ml Lubricant Oil...

Page 5: ...pper housing of the FP4 DXXX OIL to expose the oil reservoir Turn the action pin to the OPEN position and pull it off 1 Condition as delivered The FP4 DXXX OIL is delivered in a card board box Dependi...

Page 6: ...lication both connection cables with straight or angled sockets can be used Please refer to chapter 8 1 for the conditi on of the connection cable 4 Assembling the housing on the power unit of the FP4...

Page 7: ...even death Have all electrical connection work carried out by qualified personnel only Replace damaged cables or plugs immediately Before carrying out any electrical installation work observe the five...

Page 8: ...of the FP4 DXXX OIL e g cartridge empty different output signals are issued by the FP4 DXXX OIL If you have any questions about your application and the correct settings for FP4 DXXX OIL please contac...

Page 9: ...aintenance schedule for the FP4 DXXX OIL must be observed Maintenance Commis sioning After 500 hours or after 3 months Every year If required Cleaning x x x x Visual check x x x x Oil refill x x Depen...

Page 10: ...g the oil cartridge Fill the cartridge with oil until the mark max level on the oil cartridge is reached Pay attention to cleanliness when carrying out the work It is imperative that dirt and foreign...

Reviews: