Safety instructions

 

Warning! Failure to comply with the specified precautionary measures may cause serious injury to persons or damage to property.

 

The installation and commissioning may only be performed by suitably qualified persons, technicians or installers in 
compliance with safety regulations. Damage due to improper installation and commissioning, defective connectors 
on cables or any other incorrect handling will void the warranty.

 

CAUTION: 

The safety requirements are according to EN 60728-11 and must be observed.

 

 

Disconnect mains power before working on electrical systems.

 

 

Any additional electrical wiring requirements should always be installed by a suitably qualified person(s).

 

 

Installation or service work should NEVER be undertaken during electrical / thunderstorms.

 

Introduction

 

The purpose of this guide is to enable the successful installation of the Triax TVC 06 QUAD and TVQ 06 QUATRO products.

 

This guide assumes that;

 

 

The converter is connected to a suitable Triax Passive Optical Network (PON),

 

providing a minimum optical signal levels of -12/-15 dBm at the connection point of the converter.

 

 

The converter has been installed in a dry environment and mounted with suitable fixings.

 

 

The installation is carried out by a competent person.

 

 

All ferrule end faces of the FC/PC optical connectors are cleaned prior to making

 

a connection using a suitable fibre optic cleaning kit.

 

Cables and Connections

 

Cables used should be industry approved coaxial cable and should be terminated using an F type connector. Fibre optic 
cable should be Triax approved single mode with FC/PC connections.

 

Mounting

 

The device can be fixed on the wall or on a metal plat in a distributor box by using two 4 mm screws directly.

 

 
 

 

LED 

”Orange”

 

indicates when RF 
power is present

 

 

LED 

”Green”

 

indicates that unit is 
DC power supplied

 

 

Next connect the FC/PC fibre connector into the optical input of the converter 
(ensuring the end is cleaned first) as per the following diagram.

 

 

Align the 

key-way 

on the FC-PC 

connector, with the 

key-way 

on the fibre 

receptacle. Push the connector 

firmly 

into the socket.

 

 

Connector  key-way

 

 

Receptacle key-way

 

 

Ensure  the 

key-way 

are  firmly  located 

be- fore rotating the coupling ring clock-
wise onto the receptacle - se Fig. 3

 

 

2

 

Push firmly to locate key-ways

 

 

 

Coupling ring

 

 

NOTE: 

Failure to follow these instruction 

correctly will result in attenuation

 

 

 

3

 

Rotate clock-wise to finish

 

 

 

 

2/8

 

Attention:  

Never look with the eyes into a fibre line or fibre connector when an optical transmitter is connected!

 

The laser light is not visible but could damage the eye.

 

QUAD and QUATRO Optical Reconverter -  Installation Guide

 

115 mm

 

115 mm

 

1

0

5

 m

m

 

4

2

,5

 m

m

 

Summary of Contents for TVC 06 Quad

Page 1: ...User Manual TVC 06 Opto Re converter Quad Art No 307641 TVQ 06 Opto Re converter Quatro Art No 307640 User Manual Bedienungs anleitung Mode d emploi triax com ...

Page 2: ...rried out by a competent person All ferrule end faces of the FC PC optical connectors are cleaned prior to making a connection using a suitable fibre optic cleaning kit Cables and Connections Cables used should be industry approved coaxial cable and should be terminated using an F type connector Fibre optic cable should be Triax approved single mode with FC PC connections Mounting The device can b...

Page 3: ...Optical Input Input Power with TOL 32 TOL 64 or TOU 232 dBm 12 13 5 0 Wavelength nm 1310 1550 Input RF frequency range vertical GHz 0 95 3 0 Input RF frequency range horizontal GHz 3 4 5 45 Terrestrial frequency range DVB T MHz 470 854 Terrestrial frequency range DAB MHz 174 241 Terrestrial frequency range DTT MHz 88 108 Input connnector FC PC Outputs SAT Horizontal High Band input 4 4 to 5 45 GHz...

Page 4: ...eine qualifizierte Person durchgeführt Alle Metallkappen und Oberflächen der optischen FC PC Verbinder werden unter Zuhilfenahme eines geeigneten Glasfaser Reinigungssets vor dem Gebrauch gereinigt Kabel und Verbindungen Die verwendeten Koaxialkabel sollten für den industriellen Einsatz zugelassen und mit F Steckern konfektioniert sein Bei den Glasfaserkabeln sollte es sich um von TRIAX freigegebe...

Page 5: ...ischer Frequenzbereich DVB T Terrestrischer Frequenzbereich DAB Terrestrischer Frequenzbereich DTT Anschluss am Eingang Ausgänge SAT Horizontal High Band 4 4 to 5 45 GHz Vertikal High Band 1 95 to 3 0 GHz Horizontal Low Band 3 4 to 4 4 GHz Vertikal Low Band 0 95 to 1 95 GHz Impedanz nominal Rückflussdämpfung min Automatische Verstärkungsregelung AGC Ausgangspegel SAT umschaltbar Ausgänge Terrestri...

Page 6: ...x Compatibilité électromagnétique CEM Veillez au bon serrage des vis duboîtier Les câbles et les bornes de connexion ne doivent pas être oxydés Introduction Ce manuel vous guidera dans la mise en oeuvre des convertisseurs optiques TVC 06 QUAD et TVQ 06 QUATRO Hypothèses Le récepteur est connecté à un réseau optique passif PON fournissant un signal optiqueminimum de 12 15 dBm minimum Le récepteur e...

Page 7: ...al GHz 0 95 3 0 Bande de frequences horizontal GHz 3 4 5 45 Bande de frequences DVB T MHz 470 854 Bande de frequences DAB MHz 174 241 Bande de frequences DTT MHz 88 108 Connnectique d entrée FC PC Sorties BIS Bande Horizontal Haute convertie de 4 4 à 5 45 GHz MHz 1100 2150 15 5 V 22 kHz Fixe Bande Vertical Haute convertie de 1 95 to 3 0 GHz MHz 1100 2150 14 5 V 22 kHz Fixe Bande Horizontal Basse c...

Page 8: ...07 2017 Copyright Triax A S Contact triax com contact triax com ...

Reviews: