The processing units in the 

TMB100 

range are used to selectively filter digital and analogue UHF 

channels. These units also couple and amplify VHF programmes according to the satellite band 

model (IF). 

TMB100 

units have 10 UHF filters, distributed over 3 inputs with programmable bandwidth from 1 to 

7 channels (8 to 56 MHz), making it suitable for most situations. 

An individual setting for each filter or frequency band, and automatic control of the UHF output level, 

for aligning service plan levels. 

TMB-100

part no. 

360223

 with wall-plug PSU 

TMB-100-1 

part no 

360227

 with desktop PSU 

5 inputs: 

BI + FM, BIII-DAB, UHF1, UHF2, UHF3 

Gain UHF = 55 dB 

Gain BIII = 48 dB 

Gain BI-FM = 32 dB 

Output level (max.) UHF = 117 dBµV @ IMR -60 dBc 

TMB-100S

part no.  

324580

6 inputs: 

BI + FM, BIII, UHF1, UHF2, UHF3, SAT 

Gain Sat-IF = 40 dB 

Gain UHF = 55 dB 

Gain BIII = 48 dB 

Gain BI-FM = 32 dB 

Output level SAT (max.) = 118 dBµV @ IMR -35 dBc 

Output level UHF (max.) = 115 dBµV @ IMR -60 dBc 

S

S

S

a

a

a

f

f

f

e

e

e

t

t

t

y

y

y

i

i

i

n

n

n

s

s

s

t

t

t

r

r

r

u

u

u

c

c

c

t

t

t

i

i

i

o

o

o

n

n

n

s

s

s

Important: 

The unit should only be opened by a qualified technician. 

  Disconnect the unit before carrying out any work on it, as some powered components are 

dangerous (risk of electrical shock). 

  To maintain the temperature of the unit within its normal operating range, ensure the free 

circulation of air around the unit (avoid placing it in enclosed spaces). The ventilation grids 

must be free of any obstruction. 

  Ensure that no liquids can penetrate inside the unit (splashes and/or run off). 

  Do not install the unit in a damp place. If there are traces of condensation on the unit, do not 

use it until it has dried completely. 

  The mains power cable and the HF connection cables must be in good condition and free to 

move (neither crushed nor obstructed). 

  The mains plug, easily accessible for the technician, must be out of reach of children. 

Grounding of the unit 

  Your aerial installation must comply with the requirements specified by the European 

provisions EN 50083-11 (conformity of collective installations) and EN 60065 (standards in 

force for electrical protection). 

Replacing fuses 

  Only a qualified technician can replace defective fuses. 

Electromagnetic compatibility (EMC) 

  Ensure that the screws on the box are properly tightened. 

  Cables and connection terminals should show no signs of rust.

Summary of Contents for TMB 100

Page 1: ...Model Item no TMB 100 100 1 TMB 100S Version 2 1 10 2015 EN triax com TMB 100 100 1 TMB 100S Programmable Multiband Amplifier ...

Page 2: ... 6 Menus 6 Flow chart 7 Menus 8 Config menu 8 Configuration of filter distribution 8 Input amplifier setting 9 Selection of remote power supply voltage 9 Remote power supply setup 10 LTE function 10 Import and export menu 11 PIN Code 12 Language selection and Temperature display 12 UHF filters setup 13 Setting the levels 14 AGC 14 Auto level 14 SAT Menu 15 TMB 100S Diagram 16 ...

Page 3: ...ru u uc c ct t ti i io o on n ns s s Important The unit should only be opened by a qualified technician Disconnect the unit before carrying out any work on it as some powered components are dangerous risk of electrical shock To maintain the temperature of the unit within its normal operating range ensure the free circulation of air around the unit avoid placing it in enclosed spaces The ventilatio...

Page 4: ...ound the unit to ensure maximum ventilation When installing or cabling the unit we recommend you disconnect the mains power cable Connecting the unit Note UHF inputs are remotely supplied and protected against short circuits The power available is 12 or 24V 50mA max The preamplifier is detected automatically only the remote power voltage can be programmed Output Entradas UHF1 UHF2 Entrée BI FM Con...

Page 5: ...filters o UHF2 0 UHF filters o UHF3 7 UHF filters all the UHF filters are deactivated display the attenuators are at zero Factory reset If necessary to revert to factory settings follow the procedure below 1 Disconnect the power cable 2 Press the esc button and hold it 3 Connect the power cable The unit erases all the programming parameters including the PIN code and switches to standby mode You c...

Page 6: ... light segments flashes across the display Operating principle To access the configuration menus press a button To summarize To scroll through the menus use the buttons To enter a menu press enter To exit a menu press the esc button Press the Menu button to have a quick access to the CONFIG menu Note If the button is not pressed for one minute the unit switches to standby mode Menus ...

Page 7: ...Pregrammable Amplifier TMB 100 100 1 TMB 100S F F Fl l lo o ow w w c c ch h ha a ar r rt t t ...

Page 8: ...rt Export Activate the PIN code menu Select the language Ang Esp Display the internal temperature Configuration of filter distribution Unit in standby mode push a button to reach the CONFIG menu Press the enter button to reach the Comb menu Press enter again to change the configuration of the UHF inputs part of the display flashes Press the buttons or to select the distribution of the filters over...

Page 9: ...figuration of the UHF input amplifiers on off Confirm by pressing enter Selection of remote power supply voltage Unit in standby mode push a button to reach the CONFIG menu Press the enter button to select the Comb menu Press the button 2 times to reach Vdcx menu Press the enter to activate the menu Press the buttons or to select the Voltage 12 or 24 VDC Confirm by pressing enter Enter Enter CONFI...

Page 10: ...tton to select the Comb menu Press the button 3 times to reach VDCx menu Press enter to activate the menu Press the buttons or to change the configuration on off Confirm by pressing enter Press the button to reach the other inputs and repeat the process LTE function This function limits the filter setting on channel 60 CONFIG Enter Enter Enter CONFIG Comb 0010 CONFIG Comb 0010 CONFIG LTE on Enter ...

Page 11: ...reach Import or Export menu Press enter to activate the menu Press the buttons or to select the file SE00x Confirm by pressing enter The TMB units are equiped with RS232 interface please used an RS232 SD adapter to store your configuration files Important When using these menus and no SD card is available the display shows NoSD The SD MMC card should be in FAT16 format Files should be in root dire...

Page 12: ...s to reach PIN menu Press enter to activate the menu Press the buttons or to change the configuration on off Confirm by pressing enter Choose your PIN code only if on is selected o Press enter to activate the menu o Press the buttons or to change the number o Confirm by pressing enter o Do the same for the other digits Language selection and Temperature display Default PIN code 2312 ...

Page 13: ...ns or to select the start channel Confirm by pressing enter Press the buttons or to select the end channel Confirm by pressing enter Press the button to setup the next channel Notice The number of filter is according to the configuration of filter distribution In LTE mode off only channel 21 to 60 are available CHAN xP off CHAN 3P off CHAN 1P off Enter Enter Enter CHAN 1P 21 21 When channel is alw...

Page 14: ... change the value Confirm by pressing enter Press the or button to setup the next gain Notice The number of filter is according to the on off filter setting AGC Unit in standby mode push a button to reach the CONFIG menu Press the button several times to reach the Auto AGC menu Press enter to activate the AGC menu Press the buttons or to change the value Confirm by pressing enter Press the buttons...

Page 15: ...ls BI II BIII is not automatic SAT Menu TMB 100S models have one IF amplification path The Sat menu is used to configure the remote power supply of the LNB OFF 13 17 VDC to activate the 22kHz generator and the 9dB equalizer Unit in standby mode push a button to reach the CONFIG menu Press the button several times to reach the SAT menu Press enter to activate the SAT menu Press the or button to sel...

Page 16: ...anäle 8 56 MHz Filter 3 1 7 Kanäle 8 56 MHz Filter 4 1 7 Kanäle 8 56 MHz Filter 5 1 7 Kanäle 8 56 MHz Filter 6 1 7 Kanäle 8 56 MHz Filter7 1 7 Kanäle 8 56 MHz Filter 8 1 7 Kanäle 8 56 MHz Filter 9 1 7 Kanäle 8 56 MHz Filter 10 1 7 Kanäle 8 56 MHz Value UHF1 2 filter UHF2 8 7 oder 5 filter UHF3 0 1 ou 3 filter Bandwidth of the filter S1 0 12 24V 0 12 24V BI FM UHF1 VHF UHF3 OUT S2 S3 P P P P P P P ...

Page 17: ...Hz VAC Power consumption at 230VAC dependent on remote supplying W External PSU with Euro plug TMB 100 TMB 100 1 100S V A Remote supply UHF 1 2 or 3 V mA Input equiped with remote supply LNB power supply V mA 22 kHz generator on Sat input Operating temperature C MECHANICS Input output connectors Dimensions H xW x D mm CONFORMITY CE 2004 108 EC EMC Directive und 2006 95 EC Low Voltage Directive ROH...

Page 18: ...or trademarks of the TRIAX Company or its affiliates All specifications in this guide are subject to change without further notice TRIAX A S Bjørnkærvej 3 DK 8783 Hornsyld Denmark triax com support TRIAX A S Bjørnkærvej 3 DK 8783 Hornsyld Tel 45 76 82 22 00 Fax 45 88 20 04 20 mail triax triax dk www triax com ...

Reviews: