background image

Introduction 

Service tool 

1. Open a web browser window. 

2. Enter ‘http://192.168.0.100’ in the web address field. 

3. Press Enter. 

 

 4. Enter the password. 

5. Press the Log in button. 

Note:   
Password = ‘triax1234’ when the service tool is opened for the first time. 
The  Keep  me  logged  in checkbox overrides the system’s automatic time out 
function, which is activated after 20 minute’s inactivity. 

Overview 

 

Icons 

Indicates whether the service tool is communicating correctly with the headend unit. 

Green

The service tool and headend are communicating correctly. 

Red

The service tool and headend are NOT communicating correctly.

 

 

Indicates whether the headend unit is functioning correctly.   

Communication 
icon 

System icon

Configuration 
buttons

Tabs 

Misc. Buttons 

Introduction 

Green

The headend unit is functioning correctly. 

Red

The headend unit is functioning correctly.

 

Tabs 

Accesses the various tabs used to configure the headend’s input and output 
modules. 

System 

The service tool’s ‘home’ window. Provides system overview 
information and configuration activation/control. 

Input 

Tab for configuring input modules and services.   

Refer to input module manuals for information. 

CA Modules 

Tab for configuring CI modules and CA cards.   

Refer to output module manuals for information. 

Output   

Tab for configuring output modules and services. Refer to output 

module manuals for information. 

Network 

Tab for defining customer specific settings that are network 
related, e.g. Network name, ID, and for defining HD/SD channel 

numbering. 

Channel List 

Tab for viewing the channels being transmitted from the 

headend, as defined in the Input, CA Modules and Output tabs. 

Refer to input module manuals for information.   

 

Misc. Buttons 

Apply 

Stores configuration settings on the SD card located in the 

headend.  
Button colour 

Red  There are changes that have not been stored on the 

headend’s SD card. 

Grey  All changes are stored on the headend’s SD card. 

Log In/Out 

Service tool access control. 

Admin.- 

Opens the settings for service tool window, where language, 

location, time zone, and initial IP addresses are specified. 

 

 

Summary of Contents for TDH 800

Page 1: ...Model Item no TDH 800 COFDM output module 692860 692861 Version 891577A 08 2013 EN triax com Configuration guide TDH 800 COFDM output module ...

Page 2: ...c IP address 3 Physical connection to headend 3 Service tool 4 Overview 4 Icons 4 Tabs 5 Misc Buttons 5 Configuring CA modules 6 Pre requisites 6 Configuration 6 Resetting 10 Modifying 11 Deleting 11 Configuring COFDM output modules 12 Pre requisites 12 Configuration 12 Modifying 17 Deleting 17 ...

Page 3: ...ielded cable or better between the computer s network port and the configuration port on the headend Introduction 3 Introduction This document describes the configuration of the PAL Output module for the TDH 800 headend Physical installation of the module is described in the TDH 800 main unit installation guide System requirements Computer minimum requirements A computer meeting the following mini...

Page 4: ...heckbox overrides the system s automatic time out function which is activated after 20 minute s inactivity Overview Icons Indicates whether the service tool is communicating correctly with the headend unit Green The service tool and headend are communicating correctly Red The service tool and headend are NOT communicating correctly Indicates whether the headend unit is functioning correctly Commun...

Page 5: ... services Refer to output module manuals for information Network Tab for defining customer specific settings that are network related e g Network name ID and for defining HD SD channel numbering Channel List Tab for viewing the channels being transmitted from the headend as defined in the Input CA Modules and Output tabs Refer to input module manuals for information Misc Buttons Apply Stores confi...

Page 6: ...dule the output module is inserted in the headen and the TDH Service Tool is connected to the headend See the TDH 800 Headend User Guide for information on inserting the output module into the TDH 800 headend Configuration 1 Select the CA Modules tab in the TDH Service Tool 2 Press the Setup button for the CA module to be configured ...

Page 7: ...CA module is constantly monitored when the ER checkbox is enabled with the CA module being automatically reset in the event of data transmission failure Note that signal transmission will be interrupted for all the services associated with the CA module when the error recovery monitoring prompts the resetting of the CA Module The ER checkbox should not be enabled for services where signals are not...

Page 8: ...le all PIDs associated with the service that are neither audio or video related 9 Disable the Descramble all audio PIDs checkbox to limit the number of audio PIDs to be descrambled to specific languages 10 Select an audio PID to be descrambled 11 Select if required additional audio PIDs 12 Press the OK button Note that an additional language drop down list is displayed each time a language ...

Page 9: ...Introduction 9 is selected 13 Press the Submit button in the CA Module setup window The service s selected in now listed 14 Press the Apply button The following confirmation is displayed ...

Page 10: ...ns 1 Press the Setup button for the CA module to be reset 2 Press the Reset CAM button 3 Press the Yes button The CA module will be reset and service transmission through it will be temporally interrupted The ER checkbox can alternatively be enabled to automatically reset CA modules see above M D ...

Page 11: ...odule to be modified 2 Make the desired changes 3 Press the Submit button 4 Press the Apply button in the Configuration window Deleting 1 Press the Delete button of the CA module to be removed A confirmation popup is displayed 2 Press Yes on the confirmation popup ...

Page 12: ...g the output module is in position and the TDH Service Tool is connected to the headend See the TDH 800 Headend User Guide for information on inserting the output module into the TDH 800 headend Configuration 1 Select the Output tab in the TDH Service Tool 2 Press the Setup button for the first output row ...

Page 13: ...red Channel plan 2 Select the required Channel Pre defined values are loaded in the Frequency and Channel spacing fields Manual 1 Select Frequency in the Channel drop down list 2 Enter the desired frequency MHz in the Frequency field 3 Select the required channel spacing in the channel spacing drop down list Select input Input can be selected for the output module in two ways From the TDH Pool Fro...

Page 14: ...available in the TDX pool for other output modules From input module 1 Select Transparent in the Select input drop down list The Select input window is displayed 2 Check the Selected checkbox for the required input module 3 Press the OK button All the services that are active on the input module will be transmitted via the output module Additional settings 1 Make if required additional configurati...

Page 15: ...at the output module is functioning correctly Field Contents Status Whether the output module is enabled or disabled SW revision Displays the software version of the output module The software version displayed must be identical with that installed on the TDH 800 main unit and on all other input output modules Update the software for the entire TDH 800 headend including input output modules if thi...

Page 16: ...Configuring COFDM output modules 16 3 Press the Apply button The following confirmation is displayed The services selected are visible in the Channel list tab ...

Page 17: ...mit button 5 Press the Apply button in the Configuration window Deleting 1 Press the Delete button of the output module to be removed A confirmation popup is displayed 2 Press Yes to remove the output module The output module is displayed in red in the Output tab 3 Turn off the headend 4 Physically remove the output module from the headend 5 Restart the headend 6 Restart the service tool The outpu...

Page 18: ...ogo and TRIAX TRIAX Multimedia are registered trademarks or trademarks of the TRIAX Company or its affiliates All specifications in this guide are subject to change without further notice TRIAX A S Bjørnkærvej 3 DK 8783 Hornsyld Denmark triax com support 18 Manufacturer Dear Customer Should you require technical assistance in the event that your expert dealer is unable to help you please contact u...