Installation

8

Thermal Output Maxi-Flo Stainless Steel Heat Exchangers

Dimensions

Model

No.

GPM Pressure Drop

Ft

Thermal

Output

Btu/hr

Hot Water Flow

GPM Pressure Drop

Ft

Cold Water Flow

Heat Transfer

Surface

Sq. Ft.

135,000
200,000
260,000
400,000

3

2
2
2

3

12

5
6

7

13

8
9

MF-135
MF-200
MF-260
MF-400

55
65
77
93

3

95,000

6

2

7

MF-80

77

6

5
6
8

Model 

No. 

C

D

E

F Weight

lb

5 1/2" 

13 1/2"

18 3/4"
23 3/4"
41 3/4"

5 1/8" 
5 1/8" 
5 1/8" 
5 1/8" 

5 1/2" 

5 1/2" 
5 1/2" 

1"

1 1/2"

1 1/2"

2"

1"
1"

2"

MF-135 
MF-200 
MF-260 

MF-400 

MF-80 

(See below) 

 

3"

8

11

14

24

6

3"

3"

3 1/2"

1 1/2"

A

B

D

E

E

Pool Connection

"F"

Pool Connection

"F"

All Bracket

 Holes 1/4" I.D.

Boiler  

Connection"C"

Boiler  

Connection

"C"

MF Stainless Model

10"

1 1/2"

5 1/8"

16

"

3/4" Boiler Connection

3/4" Boiler

Connection

Pool Connection

1 1/2” Pool 

Connection

5 1/2"

MF-80

Summary of Contents for MAXI-FLO MF-135

Page 1: ...st be filed immediately against the transportation company by the consignee Leave all documentation received with owner for future reference STAINLESS STEEL AND TITANIUM HEAT EXCHANGER FOR SWIMMING PO...

Page 2: ...T only 7 SPECIFICATIONS DIMENSIONS MAXI FLO Stainless Steel Heat Exchanger 8 MAXI FLO Titanium Heat Exchanger 9 Following terms are used to bring attention to the presence of various risk levels or to...

Page 3: ...ture in excess of 104 F is considered unsafe for all persons Lower water temperatures are recommended for extended use exceeding 10 15 minutes and for all young children b Since excessive water temper...

Page 4: ...tors must feed downstream of the unit and have an anti siphoning device to prevent chemical back up into the heat exchanger when the pump is shut off WARNING High chemical concentrations from improper...

Page 5: ...ction See Fig 4 page 7 RECOMMENDED TEMPERATURE Swimming pool water temperature of 80 F US Swimming Rules and Regulations require pools for competition water temperature must be at 78 to 80 F Spa and t...

Page 6: ...system until the water reaches the desired temperature setting WARNING SPRING AND FALL OPERATION During cold periods those above freezing weather maintain a minimum temperature setting 65 F to 70 F f...

Page 7: ...ng From the pool Stainless Steel or CPVC Chlorinator 1 Maxi Flo Heat Exchanger 2 Boiler 3 Boiler Water Circuit 4 Sensor or Aquastat 5 Isolation Valve 6 Check Valve 7 Circulators 9 Filtration 10 Pump 1...

Page 8: ...in Valve 16 Flow Control Valve 17 Check Valve Anti siphon Device Fig 2 Recommended Piping Schematic MF 80 MF 135T MF 260T 5 17 1 12 5 5 13 4 5 9 10 5 13 14 6 115V To the pool Heating zones return Heat...

Page 9: ...ple Rubber Coupling MF 135T or MF 260T Heat Exchanger FIG 4 POOL PIPING CONNECTION MF 135T AND MF 260T ONLY Flow Switch Typ McDonnell Miller FS4 3 FIG 3 FIELD WIRING Note Recommend pipe thread sealant...

Page 10: ...400 55 65 77 93 3 95 000 6 2 7 MF 80 77 6 5 6 8 Model No A B C D E F Weight lb 5 1 2 13 1 2 18 3 4 23 3 4 41 3 4 5 1 8 5 1 8 5 1 8 5 1 8 5 1 2 5 1 2 5 1 2 1 1 1 2 1 1 2 2 1 1 2 MF 135 MF 200 MF 260 M...

Page 11: ...Ft Cold Water Flow Heat Transfer Surface Sq Ft 135 000 260 000 9 24 2 3 11 13 MF 135T MF 260T 92 92 5 6 Model No A B C D E F Weight lb 20 29 1 2 5 5 5 1 2 5 1 2 11 2 11 2 MF 135T MF 260T 4 1 4 4 1 4...

Page 12: ...0 Forest Parkway Suite 100 West Deptford NJ 08066 Tel 856 228 8881 Fax 856 228 3584 E mail sales triangletube acv com For domestic water snow melting radiant floor refrigera tion Plates made of stainl...

Reviews: