TriangleTube GPX Series Installation, Operation & Repair Parts Information Download Page 2

ed) wiring must be used. DO NOT USE 
AN EXTENSION CORD.

• To avoid risk of fire, electrical shock 

and other injuries, switch power off 
at service panel and tag prior to the 
installation.

• Do not operate fan in areas where gas 

or oil-fired equipment is in operation.

• Wear safety goggles when drilling, 

hammering, or cutting materials.

OPERATING YOUR FAN

IMPORTANT Do not operate your fan 
without first providing adequate ven-
tilation (such as a door or window) to 
provide the proper inlet airflow.
WARNING BEFORE PROCEEDING 
WITH THE INSTALLATION, SWITCH 
POWER OFF AT SERVICE PANEL. The 
fan requires a 120-volt AC power source 
with at least 5-amp capacity (10-amp for 
24" and 30" GPX). All electrical work 
must be done in accordance with local 
building codes, using approved mate-
rial. Follow the wiring diagram shown 
on next page.

ITEMS REQUIRED FOR INSTALLATION
  • Screwdriver 

• Straight edge 

  • Safety goggles  • Pencil 
  • Measuring tape   
• Electric drill
  • Power saw or hand saw 
  • (12) wood screws 1/4" x 3/4" lg.

GPX FANS ARE EASY TO INSTALL: 

1. Simply cut a square opening in the 

wall. (See chart below). 

2. Slide the fan into the opening from 

outside the structure. Using (12) 1/4" 
x  3/4" screws, attach flange to your 
structure. 

3. Connect the motor to a 120-volt, 

60-Hz single-phase power source. 

  Proper installation is required to 
achieve maximum efficiency. It is nec-
essary to provide adequate ventilation 
to meet minimum intake air require-
ments. This prevents pressure buildup, 
which will reduce the fan's efficiency. 
Inadequate intake air can also lead to 
premature motor failure.

CAUTION - SAFETY RULES

WARNING: TO REDUCE THE RISK OF 

FIRE, ELECTRIC SHOCK OR INJURY, 

OBSERVE THE FOLLOWING:

• Use this unit only in the manner 

intended by the manufacturer. If you 
have questions, please contact manu-
facturer.

• Before servicing or cleaning unit, 

switch power off at service panel and 
tag service panel to prevent power 
from being switched on accidentally.

• Installation and electrical wiring must 

be done by qualified person(s) in 
accordance with all applicable codes 
and standards, including fire-rated 
construction.

• Sufficient air is needed for proper 

combustion and exhausting of gasses 
through the flue (chimney) of fuel-
burning equipment to prevent back-
drafting. Follow the heating equipment 
manufacturer's guidelines, along with 
safety standards such as those pub-
lished by the National Fire Protection 
Agency (NFPA), the American Society 
for Heating, Refrigeration & Air 
Conditioning Engineers (ASHRAE), 
and your local code authorities.

• CAUTION Check for hidden electrical 

wiring or utility lines before cutting or 
drilling into a wall or ceiling.

• CAUTION

 

For general ventilating only. 

DO NOT use to exhaust hazardous or 
explosive materials.

• Your GPX fan will operate only on 120 

volt AC, 60Hz (cycle) current.

• A permanent, THREE-WIRE (ground-

IMPORTANT: READ INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING 

TO INSTALL, OPERATE OR SERVICE THIS FAN.

FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN 

PERSONAL INJURY AND/OR PROPERTY DAMAGE. 

  Model 

Wall Hole Size

 12 

17 

3

/

8

" square

 16 

21 

3

/

8

" square

 20  25 

3

/

8

" square

 24  29 

3

/

8

" square

 30  35 

3

/

8

" square