Fuels to use:
Sunbrite Singles and Doubles
Small size Rexco.
Coalite.
Anthracite Stove Nuts.
Welsh Dry Steam Coal Small Nuts.
COAL SHOULD NOT BE USED.
PETRO COKE MUST NOT BE USED ON THIS APPLIANCE.
Operating Too
l
A multi-purpose tool is supplied with the appliance for the
removal of the ash-pan, operation of the shaker grate and
door catch.
Lighting
1. Place wood and paper or firelighters on grate as for an
open fire. Cover with a small amount of fuel and light.
2. When fire is established, add more fuel up to the level of
the front fire bars, sloping up to the back. Do not overfill or
allow pieces of fuel to become trapped between front bars
and door as this could crack the glass.
3. Close fire door and firmly latch.
4. Set thermostat control knob to the required setting. (See
under „Control Settings‟ for guidance).
Control Settings
The rate of burning is regulated by the control knob at the top
left-hand side of the frame surround.
The required setting will usually be found by experience, since
many factors can affect the chosen position, such as the
weather conditions, chimney draught and the comfort
conditions required. However, the following settings can be
used as a guide:
Mid-winter
Setting 3 to 4
Early and latter parts
of the heating season
Domestic hot water only
Setting 2 to 3
Overnight burning
If the fire goes out open idling air disc to slightly increase the
burning rate. See Fig. 1
Refuelling
1. Do not allow the fire to burn too low before refuelling.
2. With the door closed, clear ash from the grate by inserting
tool in end of shaker bar and operate sharply up and down.
3. Add fuel to the level of the front fire bars, sloping it upwards
to the back of the fire box.
4. Firmly latch the fire door.
IMPORTANT
WHEN DE-ASHING AND REFUELLING THE BOILER A
HEAT RESISTANT GLOVE MUST BE WORN WHEN
OPENING AND CLOSING THE DOOR.
Ash Removal
The frequency is dependent upon the rate of burning, but
once a day should normally be sufficient.
Note: It is important that ash is not allowed to build up to the
underside of the grate otherwise the bars could be damaged.
To remove the ash, open the fire door and draw out the ash
pan with the multi-purpose tool and carry it outside with the
aid of the carrying handle.
Overnight Burning
With the control knob set at No. 2 to 3 the appliance can be
left for long periods without attention.
1. Clear the fire bed of ash by operating the shaker grate and
empty the ash pan if necessary.
2. Fill the firebox to the level of the front bars, sloping
backwards and upwards towards the rear of the appliance.
3. Close the door and firmly latch.
To Revive the Fire
1. Shake the grate to clear the ash.
2. Refuel.
3. Adjust the control knob to a high setting.