2.1 Introduction
This chapter describes the configuration and installation of the HPSC104-SER power supply. In
addition, section 2.2 provides a formula to calculate the ava5VDC. Figure 2-1 shows the
HPSC104-SER connectors, jumpers and other options.
Power Considerations.
The +5V switching regulator is rated at 25A maximum output, however the +5V output supplies power
to the +12, -5, and -12VDC regulators. To obtain the usable range of +5V output, “derate” according
to the use of +12, -5, and -12VDC. Use the following formulae to calculate the maximum usable
output.
Where:
I[-5] = -5VDC current load
I[-12] = -12VDC current load
I[12] = 12VDC current load
Assuming 90 percent converter efficiency (actual efficiency may vary).
9
.
0
)
4
.
2
*
]
12
[
4
.
2
*
]
12
[
]
5
[
(
25
5
I
I
I
A
Voutput
Usable
+
−
+
−
−
=
+