14
30. Install the upper casing with o-ring, ensuring that the pins on the upper casing fit into the notches
on the lower casing, and install and tighten the clamp.
31. Install the seal guard (36).
32. Install the inlet adapter (10) on the casing (11),
securing it with a clamp.
33. Install the diffuser and suction tube (7) and gasket in
the adapter (10), and secure it with a clamp.
34. Install the butterfly valve (5) and gasket, and secure
it with a clamp (3).
35. Install the hopper (1) and gasket (4) , and secure it
with a clamp (3).
MAINTENANCE
IMPORTANT: Be sure to position the adapter (10)
correctly. The adapter inlet should be
opposite the casing outlet (11). See