6
INSTALLATION
INSTALLATION GUIDELINES
UNPACKING EQUIPMENT
Check the contents and all wrapping when unpacking your equipment. Inspect all parts for damage
that may have occurred during shipping. Report any damage to the carrier.
LOCATION AND INSTALLATION
The pump unit should be located as near as possible to the
liquid source and in a position where the suction piping can be
short and direct with a minimum number of elbows and fittings.
It should also be readily accessible for inspection and cleaning.
The pump unit as received from the factory is ready for
installation. To install it, attach a hoist if necessary, loosen the
setscrews in the adjusting leg brackets, and individually adjust
the legs until the pump unit is level. Tighten the setscrews.
Attach the suction and discharge piping. Be sure suction and
discharge piping is properly supported to avoid any strain on the
pump casing.
Adjustable Leg
Bracket
Motor Foot
Setscrew
Figure One
Summary of Contents for C-Series