background image

 

6

1.  Wiring must be sized per National Electrical Code requirements based on the pump load and 

conductor length. 

2.  Conductors must be installed in approved conduit. 
3.  The pool heater, the pool pump, and the pump timer must be grounded per National Electrical 

Code requirements. 

 
Open the pool timer and connect a second set of wires to the line side terminals. Use a length of 
watertight flexible conduit to connect to the Pool Heater cabinet, entering through the openings 
provided on rear of the cabinet. Remove the left panel from the pool heater. Connect to the black 
wires labeled #1 and #2 hanging from the Pool Heater’s control box. 
 
Open the junction box on the pool pump and connect a second set of wires to the pump terminals. 
Use a length of watertight flexible conduit to connect to the Pool Heater cabinet, entering through 
the openings provided on the rear of the cabinet. Connect to the pair of blue wires, labeled #1 and 
#2, found hanging from the Pool Heater’s control box. Be sure that the polarity is correct. 
 
Replace the left panel on the cabinet.  
  

 

POOL PIPING CONNECTIONS 
 

The Pool Heater is designed to handle the full flow from the pool pump. No bypass is required if the 
water flow is in the 20 to 80 gallon per minute range. See Figure 4. 
The Pool Heater piping must be connected at a point in the pool piping loop after the pool water 
passes through the filter and before the chlorinator or chemical feeder. Connecting the Pool Heater 
after the chlorinator will cause premature failure of the Pool Heater. 

While this unit contains a 

specially coated heat exchanger to resist chlorine, failure to maintain proper pool chemistry 
will significantly shorten the life of the Pool Heater and may not be covered under Factory 
Warranty.  

To prevent back-siphoning of the chlorinator when the pool pump is turned off, install a 

chemically resistant check valve and a piping loop that extends at least 8 inches above the top of the 
chlorinator. 
 
The Pool Heater comes equipped with clear PVC stubs to allow a visual check of water flow and 
water condition. Connect to these stubs with 2 inch PVC couplings and an appropriate length of 2-
inch PVC pipe; taking care to note which stub is “water in” and which is “water out”.  
 

Good practice also suggests considering the use of 3 way valves on the inlet and outlet to enable 
the pool owner to bypass the Pool Heater if service or maintenance is required. 
 

 
 
 
 
 
 

Summary of Contents for TM121

Page 1: ...INSTALLATION OPERATING INSTRUCTIONS FOR AQUEFIER POOL HEATERS Model TM121 WCC115 Trevor Martin Corp 4151 112th Terrace North Clearwater FL 33762 Bulletin PH 121 1 ...

Page 2: ...ature even if the pool timer turns off CAUTIONS DISCLAIMERS The AQUEFIER Pool Heater operates in conjunction with your pool equipment Improper installation can cause damage to both your Pool Heater your pool pump and filter piping Only skilled technicians with appropriate training and experience should perform the installation The Manufacturer accepts no liability for equipment damage personal pro...

Page 3: ...ter temperatures to 100 degrees F c Before entering a pool or tub the user should measure the water temperature at several occupant locations using an accurate thermometer since the tolerance of the water temperature regulating devices may vary as much as or 5 degrees F d Alcohol drugs or medication should not be used before or during pool or tub use since their use may lead to unconsciousness wit...

Page 4: ... by the normal operation of the heat pump 3 Do not install the Pool Heater in an enclosed area such as a filter equipment room It is important to prevent the cool discharge air from being drawn back into the heat pump A beach location presents additional concerns Exposure to salt water spray and high winds will cause premature wear on the heat pump Salt and sand accumulation will clog up the heat ...

Page 5: ...the authority having jurisdiction Bonding to Pool Steel Electrical corrosion known as electrolysis will occur if the heater is not bonded to the pool reinforcement steel Most local codes also require that the water pump be bonded Connect using a 8 gauge or larger solid copper wire to bond the cabinet to the pool reinforcement steel Power to the Pool Pump An optional feature on the Aquifier Pool He...

Page 6: ...s designed to handle the full flow from the pool pump No bypass is required if the water flow is in the 20 to 80 gallon per minute range See Figure 4 The Pool Heater piping must be connected at a point in the pool piping loop after the pool water passes through the filter and before the chlorinator or chemical feeder Connecting the Pool Heater after the chlorinator will cause premature failure of ...

Page 7: ...ng the temperature control check the water temperature with an accurate thermometer It may be necessary to calibrate the Viconics controller in rare instances CAUTION Prolonged immersion in hot water may induce hyperthermia Hyperthermia occurs when the internal temperature of the body reaches several degrees above the normal body temperature of 98 6 degrees F The symptoms of hyperthermia include d...

Page 8: ...ed to start for an additional 3 minutes The heater will not start until at least 5 minutes has passed without resetting the breakers The heater will continue to heat the pool until the temperature setpoint has been satisfied PLEASE NOTE 1 It is important to remember that the pool heater will not run unless the pool pump is running 2 Water vapor will condense on the outside of the unit and drain du...

Page 9: ... Drop Water Flow gal min Pressure Drop psig 20 0 23 30 0 46 40 0 74 50 1 06 60 1 42 70 1 86 80 2 32 Temperature Rise Across Heater Water Flow gal min Temperature Rise deg F 20 10 0 30 6 7 40 5 0 50 4 0 60 3 3 70 2 8 80 2 5 ...

Page 10: ...10 ...

Page 11: ...11 ...

Page 12: ...12 ...

Page 13: ...13 ...

Page 14: ...bypass valves that are installed Check filtering system Check pump and impeller Check that pressure switch is closed needs 2 psi to close Wait at least 8 min without resetting on off switch or breakers Set temperature setpoint above water temperature Pool water does not reach temperature setpoint Heater runs only when pool timer is on Outside air temperature is low Turn on pool pump Install solar ...

Page 15: ... as may be authorized by an officer of Trevor Martin Corporation in a signed written document THERE ARE NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT APPLY TO THIS SALE LIMITATION OF REMEDY Trevor Martin Corporation will replace or repair at its option any product or component found to be defective during the Warranty Period either by act of Factory Service on t...

Reviews: