Reset the table: Run the table to the lowest position.
Press down again and hold for a few seconds, until the table resets.
OPERATING CONDITIONS
The table is designed to be used mostly for light assembly in dry indoor conditions. It must not be exposed to
moisture, corrosives, dust, etc. (IP20)
VOLTAGE
The table can be connected to an ungrounded network of 230 V/50 Hz or 115 V/60 Hz.
OPERATION
The maximum load capacity is marked on the table frame. The load should be divided evenly on the table top. The
table can be raised by pressing the up-arrow button on the manual controller, and lowered by pressing the down-
arrow button. The duty cycle of the motor (ED%) is 10%.
NOISE LEVEL
The noise level is under 45 dB(A) DS/EN ISO 3746.
MAINTENANCE
The motors and control unit of the table do not require maintenance. Screw couplings under stress should be
shecked at regular intervals. Dust the top of the product regularly with a duster or damp cloth. Always use the
recommended cleaning equipment and materials in ESD areas. Since dirt on ESD products can reduce their ESD
capabilities, remove dirt from the wheels regularly.
LOADING THE ADJUSTABLE TABLE
Loading capacity 150 kg with evenly loaded
NOTE! Disconnect the machine from electrical network before repairing work.
THE EU DECLARATION OF CONFORMITY
We
Treston Oy
P.O.Box 33, 40351 JYVÄSKYLÄ, FINLAND
assure that this product: LMT, Light Motor Table
complies with the Machinery Directive (2006/42/EU) and Low Voltage Directive (2014/35/EU)
Jyväskylä 2018-12-17
Kimmo Lehti
Summary of Contents for Light Motor Table LMT
Page 2: ...ASSEMBLY INSTRUCTION 905927 2018 12 14 2 15 M6 x 12 M6 x 12 ...
Page 3: ...ASSEMBLY INSTRUCTION 905927 2018 12 14 3 15 M8 x 45 M6 x 12 5 x 20 1 2 11 Nm ...
Page 4: ...ASSEMBLY INSTRUCTION 905927 2018 12 14 4 15 M8 x 8 M8 x 10 ...
Page 5: ...ASSEMBLY INSTRUCTION 905927 2018 12 14 5 15 5 SEC 4 x 20 ...