background image

 

12

HELPFUL HINTS 

The unit is fitted with a special thermal cut off device. 

Please ensure the unit is not placed against objects which will obstruct air 

intake e.g. furniture or curtains as this will affect its performance dramatically.

 

 

TROUBLE SHOOTING

 

 

 

 

 

 

Problem

 

Cause

 

Trouble shooting

 

E1 

Electrical short on both 
temperature sensor and 
PCB 

Contact an electrician for repair 
 

E2 

Electrical short of 
temperature sensor 
copper tube and PCB 
wiring 

Contact an electrician for repair 

E4 

Indicates water tank full or 
possibly the incorrect 
wiring of plug 

User needs to pull out the rubber stopper 
which is located at the bottom of the unit, to 
drain the water away. Check that the plug 
has been wired correctly. 

E8 

Filter’s life time is larger 
than 2000hrs 

Change the filter and press SPEED button 

for 3 seconds and alarm reset. 

 

13

SPECIFICATION

 

Model No.

 

TPS-M5/M55/M555 

Power Source

 

220-240V~50Hz 

Rated Power (EN60335)

 

Cooling

 

 

360W 

Cooling Capacity

 

900W 

Moisture Removed(30

 RH80%)

 

25liters/day 

Humidifying capacity 

0.2L/H 

Refrigerant

 

R410A 

Water Tank Capacity

 

2.6L 

Dimensions (mm)

 

285Wx 375Dx 500H 

(CE) N 842/2006: 

R410A is a kind of fluorinated greenhouse gases covered by 

the Kyoto Protocol. 

Its total global warming potential (GWP) is 1975

 

 

 

All features and specifications of mini portable type air conditioner stated 

in this manual are provided by the manufacturer 

This marking indicates that this product should not be disposed with 
other household wastes throughout the EU. To prevent possible 
hazards to the environment or human health from uncontrolled 
waste disposal, please recycle it to prove the sustainable reuse of 
material resources. Please ask return and collection systems or 
contact the retailer where the product was purchased to return your 
used device, they can recycle products safely.

 

Summary of Contents for TPS-M5

Page 1: ...ss 5 Clean air filter periodically to enjoy the most efficient cooling 6 When the unit is shut off please wait at least 3 5 minutes before restarting this is to prevent the compressor from being damag...

Page 2: ...provides you a remote control to help user operate all the functions easily and conveniently but also has below benefits 3 Moves easily from room to room on easy glide castors No installation require...

Page 3: ...ol receiver 3 Filter of EVA 4 Cool air outlet 5 Cool air inlet 6 Filter of COND 7 Hot air inlet 8 Remote control location 9 Hot air outlet 10 Filler 11 Drain hole 12 Water tank Optional Exhaust Hose W...

Page 4: ...to select LOW HIGH or AUTO fan speed If AUTO mode is selected during cooling function fan speed will be automatically adjusted according the surrounding temperature 7 PROGRAMMABLE TIMER TIMER ON The...

Page 5: ...TROL FUNCTION 1 While in cooling mode press the SLEEP key to set the temperature It increases1 after an hour and at most increases 2 after 2 hours 2 Press the SLEEP key again can cancel the setting 12...

Page 6: ...mally MAINTENANCE PLEASE DISCONNECT THE POWER CORD BEFORE CLEANING AIR FILTER 1 The air filter located on both sides of the unit can be removed simply by pulling the frame out 2 Wash the filter with c...

Page 7: ...3 seconds and alarm reset 13 SPECIFICATION Model No TPS M5 M55 M555 Power Source 220 240V 50Hz Rated Power EN60335 Cooling 360W Cooling Capacity 900W Moisture Removed 30 RH80 25liters day Humidifying...

Reviews: