© Copyright 2020 TRENDnet. All Rights Reserved.
TRE
NDnet User’s Guid
e
TPE-3012LS / TPE-3018LS
147
Traceroute
Diagnostics > Traceroute
1. Log into your switch
management page (see “
Access your switch management page
on page 11).
2. Click on
Diagnostics
and click on
Traceroute
.
3. Review the settings below.
Item
Description
Address Type
Specify the address type to “Hostname”or “IPv4”.
Server
Address
Specify the Hostname/IPv4 address for the host address for
traceroute.
Time to Live
Specify the max hops of hosts for traceroute.
Copper Test
Diagnostics > Copper Test
1. Log into your switch
management page (see “
Access your switch management page
on page 11).
2. Click on
Diagnostics
and click on
Copper Test
.
3. Review the settings below.
Item
Description
Port
Specify the interface for the copper test.
Copper Test Result
Port
The interface for the copper test.
Result
The status of copper test. It include:
⚫
OK: Correctly terminated pair.
⚫
Short Cable: Shorted pair.
⚫
Open Cable: Open pair, no link partner.
⚫
Impedance Mismatch: Terminating impedance is not in
the reference range.
⚫
Line Drive
:
Length
Distance in meter from the port to the location on the cable
where the fault was discovered.
Summary of Contents for TPE-3012LS