T30
-4-
Power Supply
Before any maintenance work, isolate
mains plug from power source.
The electric motor has been designed for one
voltage only. Always check that the power
supply corresponds to the voltage on the rating
plate.
Machines marked for 230 volt can also be
operated from a 220 volt supply.
Mains Plug Replacement
(UK & Ireland only)
Always check the condition of the cable and plug
before starting with your work.
Should your mains plug need replacing and you
are competent to do this, proceed as instructed
below. If you are in doubt, contact an authorised
Trend repair agent or a qualified electrician.
n
Disconnect the plug from the supply.
n
Cut off the plug and dispose of it safely; a plug
with bared copper conductors is dangerous if
engaged in a live socket outlet.
n
Only fit 13 Amperes BS 1363A approved plugs
fitted with a 13 Amp A.S.T.A approved
BS 1362 fuse (1).
n
The cable wire colours, or a letter, will be
marked at the connection points of most
good quality plugs. Attach the wires to their
respective points in the plug (see below).
Brown is for Live (L) (2) and Blue is for Neutral
(N) (3) and Green/Yellow is for earth (4) .
n
Before replacing the top cover of the mains
plug ensure that the cable restraint (4) is
holding the outer sheath of the cable firmly
and that the two leads are correctly fixed at the
terminal screws.
For 115v units with a power exceeding 1500W,
we recommend to fit a plug to BS4343 standard.
ELECTRICAL SAFETY
3
5
2
1
13 AMP
4
The vacuum cleaner is supplied from
the factory with mains supply cable
which has an earthed plug. It must
only be connected to an approved
earthed socket.
Never use a light socket. Never
connect the live (L) or neutral (N)
wires to the earth pin marked E or .
Using an Extension Cable
n
If an extension cable is required, use an
approved triple core extension cable suitable
for the power input of this tool (see technical
data).
n
When using a cable reel, always unwind the
cable completely.
n
Also refer to the table below.
Conductor size (mm
2
)
Cable rating (Amperes)
0.75 6
1.00 10
1.50 15
2.50 20
4.00 25
Cable length (m)
7.5 15 25 30 45 60
Voltage
Amperes
Cable rating (Amperes
115
0 - 2.0
6 6 6 6 6 10
2.1 - 3.4
6 6 6 6 15 15
3.5 - 5.0
6 6 10 15 20 20
5.1 - 7.0
10 10 15 20 20 25
7.1 - 12.0
15 15 20 25 25 -
12.1 - 20.0
20 20 25 - -
-
230
0 - 2.0
6 6 6 6 6 6
2.1 - 3.4
6 6 6 6 6 6
3.5 - 5.0
6 6 6 6 10 15
5.1 - 7.0
10 10 10 10 15 15
7.1 - 12.0
15 15 15 15 20 20
12.1 - 20.0
20 20 20 20 25 -