TREND 2SRM/24VAC Installation Instructions Download Page 4

2SRM/24VAC Installation Instructions TG103210 Issue 5, 11-Dec-2015.

2SRM/24VAC 

Installation Instructions

Please  send  any  comments  about  this  or  any  other  Trend  technical 

publication to [email protected]

© 2015 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls 

Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.

Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation 

to notify any person of such revisions or changes.

Trend Control Systems limited

Albery House, Springfield Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com

 

TR CU Certification

12

Switch on HVAC equipment Power Supplies

13

Check Relay operations

4 DISPoSAl

Weee Directive:

At the end of their useful life the packaging and 

product  should  be  disposed  of  by  a  suitable 

recycling centre.

Do not dispose of with normal household waste.

Do not burn.

O

I

O

I

2SRM

Supply

Supply

C

NO

NC

C

NO

NC

Channel 2 

OUT

Channel 1 

OUT

HVAC 

Equipment

2

HVAC 

Equipment

1

Note that the AUTO/ON/OFF links may be used to test 

2SRM to HVAC Equipment installation, however, when using 

manual overrides (ON, OFF), feeds switched from other 

relays on the same module, or interlocks with other relays 

may not be operative.

0V

24

V

AUT

O ON OFF

AUT

O ON OFF

J1

J2

LOW/LOWER

HIGH/RAISE

NC

NO

CN

C

NO

C

IN

2

IN

1

RL1

RL1

‘click’

2SRM

Channel 2

‘click’

Channel 1

HVAC 

Equipment 2

HVAC 

Equipment 1

3 InSTAllATIon 

(continued)

Summary of Contents for 2SRM/24VAC

Page 1: ...nstallation practices e g HSE Memorandum of Guidance on Electricity at Work Regulations 1989 USA National Electric Code Contents 1 Box Contents 1 2 Storing 1 2SRM 24VAC Installation Instructions TG103210 H O 2 10 C 14 F 70 C 158 F 0 RH 95 RH 57 mm 2 24 48 mm 1 89 83 mm 3 23 13 mm 0 51 IN 0V 24 V AUTO ON OFF AUTO ON OFF J1 J2 LOW LOWER HIGH RAISE NO NC C NO NC C IN 2 IN 0V 24 V AUTO ON OFF AUTO ON ...

Page 2: ...al 24 Vac dc supply maximum current consumed from supply 24 Vac 73 mA 24 Vdc 33 mA Note that external 24 V supply should be isolated or earthed grounded at IQ earth ground ensure correct polarity 0 V OUT 2 0 V OUT 1 IQ IQ Controller Installation Instructions 0V 24 V AUTO ON OFF AUTO ON OFF J1 J2 LOW LOWER HIGH RAISE NC NO C NC NO C IN 2 IN 1 RL1 RL2 Link for Channel 1 Low Lower relay Link for Chan...

Page 3: ...F J1 J2 LOW LOWER HIGH RAISE NC NO C NC NO C IN 2 IN 1 RL1 RL2 2SRM C NO NC C NO NC Supply Supply Channel 2 OUT Channel 1 OUT HVAC Equip ment 2 To meet safety requirements for the 2 relays OUT1 and OUT2 those being used must all be switching either low voltage or mains and not a mixture of voltages If switching mains they must all switch the same phase and polarity Contact ratings 5 A 240 Vac cosø...

Page 4: ...y House Springfield Road Horsham West Sussex RH12 2PQ UK Tel 44 0 1403 211888 Fax 44 0 1403 241608 www trendcontrols com TR CU Certification 12 Switch on HVAC Equipment Power Supplies 13 Check Relay Operations 4 Disposal WEEE Directive At the end of their useful life the packaging and product should be disposed of by a suitable recycling centre Do not dispose of with normal household waste Do not ...

Reviews: