Appendix
33
MODBUS RTU | SPI 3 | Trebing & Himstedt
2
Bit 7
1
…6 …5 …4 …3 …2 …1 …0
Byte 0
…3
…2
…1
OUT
Bit 7
1
…6 …5 …4 …3 …2 …1 …0
Byte 0
…3
…2
…1
IN
Send telegram fragment
Send telegram 1
User data
D
E
F
Receipt telegram 1
Request (DP Master)
Response (SPI 3)
Send user data in telegram fragments (only toggle Bit 1 in Byte 0, specify further user data from Byte 1 onward)
…n
…n
…
1
1
Receipt telegram fragment
3
Bit 7
1
…6 …5 …4 …3 …2 …1 …0
Byte 0
…3
…2
…1
OUT
Bit 7
1
…6 …5 …4 …3 …2 …1 …0
Byte 0
…3
…2
…1
IN
Send telegram fragment
Send telegram 1
User data
H
I
J
Receipt telegram 1
Request (DP Master)
Response (SPI 3)
Send further user data in telegram fragments (toggle only Bit 1 in Byte 0, specify further user data from Byte 1 onward)
…n
…n
…
0
0
Receipt telegram fragment
4
Send further user data in telegram fragments – until telegram 1 has been sent completely
(only toggle Bit 1 in Byte 0, specify further user data from Byte 1 onward)
5
Send next telegram (only toggle Bit 0 in Byte 0, specify telegram length in Byte1, specify user data from Byte 2 onward)
Bit 7
0
…6 …5 …4 …3 …2 …1 …0
Byte 0
…3
…2
…1
OUT
Bit 7
0
…6 …5 …4 …3 …2 …1 …0
Byte 0
…3
…2
…1
IN
Send telegram 2
Telegram length
User data
0x8
L
S
Receipt telegram 2
Request (DP Master)
Response (SPI 3)
…n
…n
…
0
0
6
Send further user data in telegram fragments – until telegram 2 has been sent completely
(only toggle Bit 1 in Byte 0, specify further user data from Byte 1 onward)