Sintel-3 VM Instruction Manual 

ENGLISH 

     While the voice guided menu instructs you on how to program the dialler be sure to:      

• 

Wait that the voice has terminated before pressing any key.  

        
        After any request, you may exit the voice programming mode by pressing the ( * ). If no button is pressed for a  
        period of time, the SINTEL-3VM will automatically exit the programming mode. 
 
,      If a number must be memorized, the ( * ) may serve as a pause.  ( see 4.0 below)  The ( # ) must be pressed 
       at the end of the number inserted.  The OK & NO buttons are not active during this function.  

• 

During the playback of a number, if a BEEP is heard, it will mean that there is a one second  pause between 
the 2 numbers.  A longer pause is possible by pressing the ( * ) key more times.   

• 

To cancel  a memorized  telephone  number,  you  must  press  the  (  #  )  button  and  then  select  the  channel  and 
position  of  the  number  to  be  cancelled.    If  there  is  no  number memorized  in  this  selected  position,  the  voice 
menu will indicate it by saying “NO NUMBER PROGRAMMED.”. 

• 

If you, by error,  press an incorrect button, the voice menu message will be repeated. 

• 

When a channel is requested by the voice menu, you must choose 1-2 or 3.  All other button will not be active. 

• 

When the voice menu requests the position of the memorized telephone number, you must choose from 1 to 5.   

        All other button will not be active.    

• 

To stop the dialler’s call cycle from a remote telephone during an alarm trigger,It is necessary that the ( * ) 

       button be pressed.  This function, however, must be programmed for each number when memorized. 

• 

Both the technical and the user access codes are made up of 6 figures.  So you must input only 6 digits. 

• 

After having memorized a new access PIN code the, the dialler will automatically exit the programming mode 
and sound a beep confirmation.   To go back into programming mode you must enter the new access code. 

        
       The memorized messages have a duration of 10 seconds each and recording must start 3 seconds after the  
       voice menu request. 

• 

After having memorized a voice message, the guided menu will ask “how many times it must be repeated” 

       (from 1 to 9).  Only after the messages have been repeated based on the number programmed, it will be  
       possible to stop by remote by pressing ( * ) the dialler trigger cycle.  

• 

The REMOTE  FUNCTION  will allow an end user to change the state of the on board relay.  This function must 
be activated during the programming phase. If this function is active,  you must call the dialler which will reply  
after 7/8 rings.  The dialler voice menu will ask you to enter the User  code  pin  code.  If the code is not correct 
the dialler will indicate it and hang-up the line.  If it is correct, the voice menu will let you have the present  

       status of the relay and by pressing the the (1) button the relay will change state and give confirmation.   
       After confirmation, you may go ahead and change the state of the relay or hang-up.  

• 

The choose of ALARM ATTIVE WITH must be combined with one of the 4 possible selections available.   

       If non of these chooses are selected with the OK BUTTON, the request will start once again. 

 

To put the SINTEL 3 VM into normal functioning mode, PRESS ( * ). 
 

4.0.  Normal Functioning Information  

 

During normal dialler functioning, if 1 of the 3 channels receives an alarm trigger command, it will react by sending 
to all numbers memorized, on that channel, an alarm trigger cycle following the assigned tel. number positions.  
If no number  has been memorized in the channel triggered, no telephone calls will be made.    
In the case of an alarm trigger,  the dialler cycle of calls can be blocked using 3 methods. 
1-  By applying a high voltage max. (+12Vdc.) or a low voltage (zero volts) to terminal 12, any variation between the 
high and low voltage will  cause the alarm trigger to stop. 
2-  From a remote telephone, after having listened to the trigger message, (if the reset on number called is active) 
By pressing the ( * ) button the dialler call cycle will be automatically reset. 
3-  On the SINTEL-3VM keypad, digit the one of the 2 Pin codes. The Pin code must be pressed slowly and a beep 
must be heard after each number pressed.  After inserting the Pin code, the dialler trigger will automatically stop.      

 

Before the trigger message is sent, the dialler waits to hear a voice.  In the case of a busy signal, the dialler will  
continue the dialling cycle and call the next memorized number. (a maximum of 40 cycles may be programmed.)                                  

 

When the power voltage to the dialler goes to (+10,5 Vdc.), the SINTEL 3 VM, if programmed to do so, will send a 
low voltage alarm to the first number in channel 1
.  The same will take place when the voltage is back to normal 
again. (+12Vdc.)  

 

If any of the 3 channel are triggered before powering up the dialler, no alarm will be triggered. (they must first be re-
set). During an alarm cycle, if an incorrect PIN is inserted, the cycle will continue until the correct PIN is inserted. 

 

Note:  It is very important to have a good ground connection on the terminal block 2.  This for thunder storms etc. 