background image

TRAXXAS.com

Traxxas, 1100 Klein Road, Plano, TX 75074, 

Phone: 972-265-8000, Fax: 972-265-8011, e-mail: [email protected]

Traxxas encourages you to register your charger online at Traxxas.com/register.

EZ-Peak  5amp  NiMH  AC/DC  Fast  Charger                                   

The Traxxas EZ-Peak 5amp is a versatile, easy-to-use peak-detecting charger that can be 
operated with convenient AC power (100-240V) in your shop or at the track or with DC 
power (12-18VDC) for field use. The EZ-Peak 5amp’s advanced software and adjustable 
charge rate make it simple to charge all common NiMH and NiCad 4-8 cell (4.8-9.6V) R/C 
batteries. EZ-Peak 5amp uses sophisticated peak-detecting technology to make certain 
your battery pack receives a full charge for maximum performance and run time. The 
built-in receiver plug port allows the EZ-Peak 5amp to charge receiver batteries without 
an adapter. A 5-volt/1-amp USB port is also provided for convenient charging of phones, 
music players, and other devices. 

DO NOT use EZ-Peak 5amp with LiPo, LiIon, or 

LiFe batteries. 

WARNING!

 

For best charging results and your safety, it is essential 

that you read and understand these instructions before using the EZ-Peak 5amp. 
Charging and discharging batteries has the potential for serious injury and damage 
to property. Use care when charging and follow all instructions and cautions.

1. Plug the AC cord into the charger and insert the 
plug into an AC outlet. If using DC power, connect 
the DC cord to the charger and attach the alligator 
clips to a 12-18VDC power supply or battery. When 
the charger is powered on, the LEDs will light in 
sequence from left to right to confirm all the LEDs are 
functioning properly. 

2. Insert the correct charge 
lead for your connector 
type into the Charger 
Output ports. 

CAUTION:

 

Be sure to observe correct 
polarity; install the red (+) 
wire into the red (+) port 
and the black (-) wire into 
the black (-) port.

3. Plug the battery into the 
charge lead.

DO NOT use the receiver port and +/- output ports simultaneously to charge a 
receiver battery and another battery simultaneously. This will damage the charger. 

NEVER charge receiver batteries at more than 1amp. Charging at higher charge rates 
may overheat the battery, causing permanent damage.

Note: 

The EZ-Peak 5amp features a port for charging receiver packs. Simply plug 

the receiver pack directly into the port.

4.  Select the charge rate by pressing the CHARGE RATE button. The EZ-Peak 5amp will 

advance to the next charge rate each time you press the button. Higher charge rates 
will decrease charge time, but may reduce the battery’s cycle life. Traxxas suggests the 
maximum charge rate of 5amps be used only for batteries with capacities over 3400mAh. 

WARNING!

 

NEVER

 

charge LiPo, LiIon, or LiFe batteries with the EZ-Peak 5amp. Charging 

lithium batteries with EZ-Peak 5amp will cause catastrophic battery failure, including fire. 

5.  Press and hold the START/STOP button to begin charging. The EZ-Peak 5amp 

will beep once and the first Charge Status LED will glow to indicate charging is in 
progress. 

Note: 

Regardless of the battery’s initial charge level, EZ-Peak 5amp’s Charge 

Status LEDs will always light in sequence from left to right as the battery charges.

 

Note: 

If you wish to stop charging before the EZ-Peak 5amp indicates the pack is fully 

charged, press and hold the START/STOP button. The EZ-Peak 5amp will beep once, and 
the Charge Status LEDs will turn off to indicate charging has been halted.

WARNING!

 

Do not leave the charger and battery unattended while charging. 

Monitor the battery while charging. It is normal for the battery to become warm as it 
nears full charge, but the battery should not become hot. If the battery becomes hot (over 
122° F) while charging, disconnect it from the charger immediately. 

6.  When the EZ-Peak 5amp detects the battery is fully charged, it will beep 10 times, 

and the green Charge Status LED will remain lit until the battery is disconnected. 

 

Tip:

 

EZ-Peak 5amp features a battery-disconnect alarm. If the battery is disconnected 

while charging, EZ-Peak 5amp will beep at one-second intervals and flash the Charge 
Status LEDs. To switch off the alarm, press and hold the START/STOP button.

  Tip:

 

EZ-Peak 5amp features an internal safety timer that will shut the charger off if battery 

voltage peak is not detected after 90 minutes. If this occurs, the charger will display Error 
Code 7. Refer to 
EZ-Peak 5amp Charger Error Codes for more information. 

 

Tip:

 

EZ-Peak 5amp beeps each time the CHARGE RATE and START/STOP buttons are 

pushed. To turn this feature off, press CHARGE RATE and START/STOP at the same time. 
Repeat to turn the beep feature back on.

Using the USB Port                                                

Plug your USB-compatible device into the USB charge port to power or begin charging 
your USB-compatible devices. The port may also be used while charging R/C batteries.

Charger Specifications                                         

AC Input .................................................................................................................100-240V
DC Input ......................................................................................................................12-18V
Charge Current Range ................................................................ 1.0–5.0A (50W Max.)
NiCad/NiMH Battery Cell Count .................................................. 4-8 Cells (4.8-9.6V)
Receiver Battery Charging ..................................................4-5 Cells (4.8-6.0V) at 1A
USB Charging ..............................................................................................................5V/1A
Net Weight .....................................................................................................................340g
Dimensions ......................................................................... 147mm x 104mm x 40mm
Protection .......................................... Reverse polarity, short circuit, and overload
Trickle-Charge Current................................................... 1/20 of fast-charge current
AC Power Cord .........................Type SPT-2; 2x18AWG diameter w/C7 plug type
DC Power Cord ....................... Type SPT-2; 2x18AWG diameter w/C8 plug type

Battery Voltage                                         

EZ-Peak  Charger  Error  Codes                                         

Warranty Information

Traxxas electronic components are warranted to be free from defects in materials and 
workmanship for a period of 30 days from the date of purchase. 

Limitations

: Any and all warranty coverage does not cover replacement of parts and 

components damaged by abuse, neglect, improper or unreasonable use, crash damage, 
water or excessive moisture, chemical damage, improper or infrequent maintenance, 
accident, unauthorized alteration or modification, or items that are considered 
consumable. Traxxas will not pay for the cost of shipping or transportation of a defective 
charger to us. This warranty is limited to the charger only and does not cover batteries 
or other accessories used in conjunction with the charger.

Traxxas Lifetime Electronics Warranty

After the expiration date of the warranty period, Traxxas will repair the EZ-Peak 5amp 
for a flat rate of $30.00 U.S. plus $5.00 U.S. for shipping and handling. Other mechanical 
repairs will be estimated separately. The covered repairs are limited to non-mechanical 
components that have NOT been subjected to abuse, misuse, or neglect. Products 
damaged by intentional abuse, misuse, or neglect may be subject to additional charges.

Traxxas liability, in no case, shall be greater than the actual purchase price of this 
product. For replacement, product must be returned in brand new condition, with 
packaging and itemized sales receipt.

Using  the  EZ-Peak  5amp  Charger                                                 

Error 

Code

Explanation

Solution

1

The battery is 

disconnected from the 

charger or there is a 

bad connection to the 

charger. 

a.  Check the connection between the charger and 

the battery.

b.  Press and hold the START/STOP button to turn 

off the alarm.

2

There is a short circuit 
on the charge output.

Check the charge lead and the battery for a short.

3

The battery polarity

is reversed.

Make sure the charge lead is connected properly to 

the charger. If the charge lead is connected properly, 

then check the battery wiring to ensure it is wired 

correctly.

4

DC input voltage is 

out of range.

Check the DC voltage input. It may be too high 
(greater than 18V) or too low (less than 12V).

5

The number of 

battery cells is too 

low.

Charger will only operate with  4-, 5-, 6-, 7-, or 8-cell 

battery packs.

6

The internal charger 

temperature is 

too high.

Verify that the fan is operating during charging. 
If it is not, the charger may overheat. If the fan is 
operating correctly and you continue to receive 
this error, contact Traxxas Support.

7

The internal 

90-minute safety 

timer has expired. 

a. If the battery is very hot, discontinue use of the 
charger and contact Traxxas Support.
b. The charge rate is too low. Select the charge rate 
for your battery from the Maximum Recommended 
Charge Rate table to ensure the safety timer does not 
expire before the charge has completed.

Number of 1.2V Cells

Rated Nominal Voltage

4

4.8V

5

6.0V

6

7.2V

7

8.4V

8

9.6V

Battery Capacity (mAh)

Charge Rate (A)

600-1400

1

1400-2000

2

2000-2700

3

2700-3400

4

3400-5300

5

Maximum Recommended Charge Rates

Reviews: