background image

SC250X FLOOR GRINDER 

 |  OPERATIONS MANUAL

5

Traxx Constructions Products Operations Manual – SC250X Floor Grinder                                                                                             5

 

5. FAULT DIAGNOSIS 

 

Symptom 

Possible Cause 

Action 

 
Grinder runs for 5-15 minutes, then 
stops 
 

The current screw is not adjustable  

Adjust the current screw to the 
suitable area 

Extension cable too long and/or not 
made from heavy enough cable 

Get electrician to check extension lead 
compatibility 

Grinder runs but does not perform 
adequately 

Motor defective 

Repair or replace 

Grinder vibrates during use 

Grinding plates not correctly placed 

Replace or re-balance grinding plates 

Grinding noise coming from grinding 
head when up on jockey wheel 

Excessively worn motor bearings 

Have motor serviced 

 
 

Symptom Possible Cause Ac

6.   MAINTENANCE 
 

Daily cleaning: The motor in use should always be kept clean. No water drops, cotton etc should be allowed to get into 
the interior of the motors. 
 
Check on load current: While the motor is in operation, constant care should be taken to keep the load current below 
the rated value. 
 
Operational sounds: During operation of the motor there must be no rubbing sounds, shrieks or other random noises. 
Stop the motor immediately and restart after inspection and corrections have been made. 
 
Check folding handle latch periodically. This is adjustable. 
 
To adjust, loosen adjusting handle and adjust handle height until a satisfactory tension 
has been achieved. 
 
The wheel bearings use sealed bearings and require no regular greasing.

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

Dec 2017

6. MAINTENANCE

5. FAULT DIAGNOSIS

Summary of Contents for SC250X

Page 1: ...Unit 4 1 Rocklea Drive Port Melbourne Vic 3207 1300 109 108 www traxxcp com au SC250X FLOOR GRINDER OPERATIONS MANUAL ...

Page 2: ...ed Traxx Construction Products has composed this manual with accuracy However mistakes may occur or articles may be changed Traxx Construction Products is not responsible for mistakes or deviations of figures graphics or any other information found in this instruction manual 1 CONTENTS 2 2 INTRODUCTION DESCRIPTION 3 3 TECHNICAL DATA 3 4 OPERATION 4 5 SAFETY PRECAUTIONS 4 6 FAULT DIAGNOSIS 5 7 MAIN...

Page 3: ...ction with an appropriate industrial vacuum unit eliminates dust loss during grinding The shroud has 2 removable sections to enable the operator to grind close up to the wall etc Please note that dust loss is possible when this section is removed The floor grinder comes complete with a water connection for wet grinding should this be required This incorporates a ball valve allowing the operator to...

Page 4: ...ng the handles you can fix vertical grinding position photo 1 2 You can adjust the axle s width for your need photo 2 4 SAFETY PRECAUTIONS The Floor Grinder has been designed to minimize noise and vibration levels and to provide maximum operator safety However incorrect use of the grinder may cause serious injury and therefore the following precautions must be taken 1 Do not use the grinder for lo...

Page 5: ...eel Excessively worn motor bearings Have motor serviced Symptom Possible Cause Ac 6 MAINTENANCE Daily cleaning The motor in use should always be kept clean No water drops cotton etc should be allowed to get into the interior of the motors Check on load current While the motor is in operation constant care should be taken to keep the load current below the rated value Operational sounds During oper...

Page 6: ...ER OPERATIONS MANUAL 6 Traxx Constructions Products Operations Manual SC250X Floor Grinder 6 7 PARTS DIAGRAM Traxx Constructions Products Operations Manual SC250X Floor Grinder 6 7 PARTS DIAGRAM Dec 2017 7 PARTS DIAGRAM ...

Page 7: ... 26 100263 big clip 2 27 100222 flexible conduit L 245 1 100264 small clip 2 28 100249 crossover coupling 1 29 100249 crossover coupling 1 30 100666 Frame body part 1 31 100245 Inner hexagon spanner 1 32 100307 flat washer 12 2 33 100667 Hexagon jam nuts 2 34 100668 Big plain washers 2 35 100669 power cord 1 36 100670 Cross recessed pan head screw M4X16 3 37 100223 breaker GV2 ME16C 1 100224 break...

Page 8: ...Unit 4 1 Rocklea Drive Port Melbourne Vic 3207 1300 109 108 www traxxcp com au ...