background image

FOR YOUR OWN SAFETY AND THAT OF THE PRODUCT, PLEASE READ THIS USER 
GUIDE CAREFULLY BEFORE BEGINNING SET-UP AND INSTALLATION.

CAUTION: DO NOT OPEN OR HANDLE THE PANELS EXCEPT AT A STATIC FREE 
WORKSTATION OR WEARING AN ANTISTATIC WRIST STRAP. 

The 64PXL Mirror Wash RGB is part of the Traxon

 Panels product line, enabling a flexible 

setup of medium to large scale RGB LED color changing walls. The 64PXL Mirror Wash RGB 
features 64 individually addressable pixels for full programming liberty.

• 64 individually controllable

   RGB SMDs

• Seamless color transition

   between the pixels

• DMX / e:pix Control
• TX Connect Smart Cabling

2. PACKING CONTENTS

1

2

1. INTRODUCTION

64PXL MIRROR WASH RGB 

(PA.MI.7110002)

1 x 64PXL Mirror Wash RGB

1 colors 
     PANTONE BLACK M

4 x Mounting Screws

1 x TX Connect Smart Interconnection Cable (80cm/31.5”)

This product is designed for indoor use only.

An ambient operating air temperature range of

 0°C~40°C (32°F ~ 104°F) must be 

adhered to at all times. 

DO NOT disassemble. The product has no user serviceable parts. 

DO NOT use the product if the cover shield is broken.

If the product has been transported or stored in low temperatures, DO NOT connect it to the 
power supply until it has reached room temperature, to prevent any internal condensation 
from damaging the product’s electronics.

DO NOT expose the product to moisture, extreme heat or direct sunlight. Use in a clean and 
dust free environment.

Avoid looking directly into the LED light at a close distance.

3. SAFETY PRECAUTIONS

DANGER – ENSURE THAT MAIN POWER SUPPLY IS UNPLUGGED BEFORE 
INSTALLING OR WIRING THE PRODUCT. 

Failure to adhere to the following instructions could result in death, serious injury, or property 

damage, and will void the product warranty.

CAUTION – POWER/DATA SUPPLY MUST BE INSTALLED BY A QUALIFIED 
ELECTRICIAN OR TECHNICIAN IN ACCORDANCE WITH RELEVANT LOCAL 
STANDARDS AND REGULATIONS. 

DO NOT ATTEMPT TO INSTALL OR USE THE PRODUCT UNTIL YOU HAVE READ 
THIS MANUAL THOROUGHLY AND UNDERSTAND THE INSTALLATION 
INSTRUCTIONS. 

DO NOT USE THE PRODUCT IF ANY CABLES ARE DAMAGED. 

340mm/13.4”

95mm/3.7”

500mm/19.7”

340mm/13.4”

SIDE

FRONT

BACK

500mm/19.7”

Summary of Contents for 64PXL

Page 1: ...he latest updates and changes on the TRAXON website 2010 TRAXON TECHNOLOGIES ALL RIGHTS RESERVED WWW TRAXONTECHNOLOGIES COM USER MANUAL 64PXL MIRROR WASH RGB PA MI 7110002 6 10 V1 1 2 colors PANTONE BLACK M PANTONE 400 M ...

Page 2: ...2 4 INSTALLATION AND SYSTEM CONFIGURATION 3 4 1 MOUNTING DIN RAIL 3 4 2 MOUNTING DIRECT TO WALL 4 4 3 CONNECTION 4 4 4 CONTROL 6 4 5 POWER CONNECTIONS 6 5 TROUBLESHOOTING 7 6 CARE AND MAINTENANCE 7 7 TECHNICAL SPECIFICATIONS 8 8 WARRANTY STATEMENT 8 1 colors PANTONE BLACK M ...

Page 3: ... DO NOT disassemble The product has no user serviceable parts DO NOT use the product if the cover shield is broken If the product has been transported or stored in low temperatures DO NOT connect it to the power supply until it has reached room temperature to prevent any internal condensation from damaging the product s electronics DO NOT expose the product to moisture extreme heat or direct sunli...

Page 4: ...ontrol up to four 64PXL panels two panels per DMX512 output Connect the Micro Server to the 64PXL panels as shown in Fig 4 4 2 MOUNTING DIRECT TO WALL Use a pencil or chalk to mark the horizontal alignment before installation Install four screws to the wall leaving minimum clearance Fig 1 Reverse the 4 mounting plates on the Panel Hang the panel on the wall as shown in Fig 3 Fig 3 Direct Screw Mou...

Page 5: ... 192 16 46 48 15 43 45 14 40 42 13 37 39 12 34 36 11 31 33 10 28 30 9 25 27 8 22 24 7 19 21 6 16 18 5 13 15 4 10 12 3 7 9 2 4 6 1 1 3 48 142 144 47 139 141 46 136 138 45 133 135 44 130 132 43 127 129 42 124 126 41 121 123 40 118 120 39 115 117 38 112 114 37 109 111 36 106 108 35 103 105 34 100 102 33 97 99 Fig 4 64PXL Panel System Connection Example CAUTION PLEASE ENSURE THAT THE POWER IS SWITCHED...

Page 6: ... smooth Data cable length exceeds 100m 330ft Check the connections of the controller and panels Check that the power supply is connected and the power is ON Check the controller configuration DC power cable length exceeds 30m 99ft 5 TROUBLESHOOTING 6 CARE AND MAINTENANCE Traxon products are of superior design and quality and should be treated with care The recommendations below will help fulfill a...

Reviews: