Installation Guide
IG0107EN V1.0 09/20
9 of 20
NOTE: Any water ingress incurred due to improper installation of cable connectors or
Waterproof Quick Lock End Caps will not be under warranty by Traxon Technologies.
3. Be sure not to compress the IN/OUT cables.
NOTE: To keep LED pitch consistent and allow for thermal expansion, be sure to keep a
minimum distance of 4mm (0.16”) between consecutive ARCHISHAPE
®
Tube Ultra Slim
(see below diagram).
FIG.8: Fixing the Brackets to Installation Surface
To maintain consistent LED pitch and to allow for thermal expansion for Tubes.
End Cap Seal on Last Tube
>4~10mm
4. The first tube of the daisy-chain group has to be connected to the control system via
Waterproof Junction Box (not included).Starter cables, Data and Power cables, and
video fiber optic cables have to be installed through conduits/trunking.
FIG.9: Bad vs. Good trunking. It is recommended to follow the example on
the right.
BAD TRUNKING (WILL VOID WARRANTY)
GOOD TRUNKING (RECOMMENDED)
5. Set up the control system indoors as detailed in the System Diagram and connect to the
ARCHISHAPE
®
Tube Ultra Slim outside. Start up each unit and verify correct function.