background image

ARCHISHAPE

®

 Tube Ultra Slim

INSTALLATION GUIDE

V1.0

Cover:

ARCHISHAPE

®

 Tube Ultra Slim

Summary of Contents for ARCHISHAPE Tube Ultra Slim

Page 1: ...ARCHISHAPE Tube Ultra Slim INSTALLATION GUIDE V1 0 Cover ARCHISHAPE Tube Ultra Slim ...

Page 2: ...CATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide IG0107EN V1 0 09 20 2 of 20 CONTENT 1 INTRODUCTION 3 2 INSTALLATION 6 3 SAFETY AND OPERATION 10 4 SYSTEM CONFIGURATION 11 5 CARE AND MAINTENANCE 16 6 TROUBLESHOOTING 17 7 TECHNICAL SPECIFICATION 18 8 WARRANTY STATEMENT 19 For your own safety and that of the product please read this installation guide carefully before beginning setup a...

Page 3: ...000 10 AS TUBE RGBW 500 5PXL 48V DV 500 5 AS TUBE RGBW 300 3PXL 48V DV 300 3 AS TUBE RGB 1000 10PXL 48V DV 1000 10 AS TUBE RGB 500 5PXL 48V DV 500 5 AS TUBE RGB 300 3PXL 48V DV 300 3 AS Tube DW 1000 10PXL 48V DV 1000 10 AS Tube DW 500 5PXL 48V DV 500 5 AS Tube DW 300 3PXL 48V DV 300 3 ARCHISHAPE Tube Ultra Slim is an IP66 rated slim LED tube for any wall or façade media lighting Available in 300 5...

Page 4: ... 1 ARCHISHAPE Tube Ultra Slim See DETAIL A See DETAIL B A B2 C1 C2 B1 DETAIL B 6 30 4 5 26 35 DETAIL A 37 6 15 5 17 26 11 4 35 4 5 Lorem ipsum dolor sit amet consectetuer Tube length A Cable length B1 Cable length B2 1000 200 160 500 200 160 300 200 160 Bracket position C1 Bracket position C2 160 160 160 160 80 120 FIG 2 ARCHISHAPE Tube Ultra Slim Accessories End Cap with 120 Ohm 50 φ14 Starter Ca...

Page 5: ... TRAXON TX CONNECT ARE TRADEMARKS OF TRAXON TECHNOLOGIES U S PATENTS E U PATENTS JAPAN PATENTS OTHER PATENTS PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide IG0107EN V1 0 09 20 5 of 20 1 3 Packing Contents FIG 3 Packing Contents ARCHISHAPE Tube Ultra Slim x 1 ...

Page 6: ...s cable gauges described in below diagram Please consult your local Traxon office or authorized agent for necessary aid The number of ARCHISHAPE Tube Ultra Slim and appropriate LED Engines DMX512 to be used to control the ARCHISHAPE Tube Ultra Slim Distance between each Tube for thermal expansion and maintaining pixel pitch Mounting distances should be paid attention on Proper surge protection FIG...

Page 7: ...d LED Engines and ARCHISHAPE Tube Ultra Slim in an indoor environment Ensure all the Interconnection Cables ARCHISHAPE Tube Ultra Slim and LED Engines are initially stored in a dry area to guarantee the complete sealing of the system from water before installation 2 2 2 Bracket Screws are needed to fix the bracket The schematic diagram of the bracket is as follows FIG 5 ARCHISHAPE Tube Ultra Slim ...

Page 8: ...x brackets to installation surface with anchor bolts FIG 6 Fixing the Mounting Clip to Installation Surface Tube to Tube Clearance To maintain consistent LED pitch and to allow for thermal expansion for Media Tubes End Cap Seal on Last Tube 4 10mm Bracket mounting 1 2 ST3 5mm x 4 Not included 2 The ARCHISHAPE Tube Ultra Slim are interconnected using the IN and OUT cables on each end of the tube Sc...

Page 9: ...inimum distance of 4mm 0 16 between consecutive ARCHISHAPE Tube Ultra Slim see below diagram FIG 8 Fixing the Brackets to Installation Surface To maintain consistent LED pitch and to allow for thermal expansion for Tubes End Cap Seal on Last Tube 4 10mm 4 The first tube of the daisy chain group has to be connected to the control system via Waterproof Junction Box not included Starter cables Data a...

Page 10: ...his product is designed for indoor and outdoor use Ensure product operates within the specified temperature range Refer to 7 TECHNICAL SPECIFICATION for more details Do not attempt to open the product Not user serviceable Do not use the product if any part of it or the power cables are damaged Only use product for specified voltage do not exceed Refer to 7 TECHNICAL SPECIFICATION for more details ...

Page 11: ...ide IG0107EN V1 0 09 20 11 of 20 4 SYSTEM CONFIGURATION 4 1 ARCHISHAPE Tube Ultra Slim Connection Components The ARCHISHAPE Tube Ultra Slim is connected using a daisy chain system with power and data on the same cable Below diagram shows some typical components for ARCHISHAPE Tube Ultra Slim system FIG 10 Connection Components for ARCHISHAPE Tube Ultra Slim System LED Engine 240W 48V Outdoor Cable...

Page 12: ...im are controlled by DMX512 Each pixel on the Tube uses three RGB 3 in 1 LEDs and three white LEDs with twelve channels for R G B and W Pixel number 1 begin on the IN connector side and it uses the first four channels The start address is the next address from the previous tube in the daisy chain 1 RGBW 4 in 1 Pixel RGBW 4 in 1 LED RGBW Pixel n Control Channel Number R Tube start address 4 n 1 G T...

Page 13: ... of 20 1 RGB Pixel 1 White Pixel RGB LED White LED RGB W Pixel n Control Channel Number R Tube start address 4 n 1 G Tube start address 4 n 1 1 B Tube start address 4 n 1 2 W Tube start address 4 n 1 3 Where n is pixel number along the Tube Pixel 1 is located near the IN connector 1 RGB Pixel RGB LED RGB Pixel n Control Channel Number R Tube start address 3 n 1 G Tube start address 3 n 1 1 B Tube ...

Page 14: ...TS E U PATENTS JAPAN PATENTS OTHER PATENTS PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide IG0107EN V1 0 09 20 14 of 20 1 RGB Pixel 1 White Pixel WW LED CW LED DW Pixel n Control Channel Number WW Tube start address 2 n 1 DW Tube start address 2n Where n is pixel number along the Tube Pixel 1 is located near the IN connector ...

Page 15: ...lation engineer should use appropriate plugs for outdoor connection DMX In AC In 300mm LED Engine 240W 48V Starter Cable TUBES ARE DAISY CHAINED Signal 48V DMX DMX Ground Wire Size AWG 17 AWG 24 AWG 24 AWG 17 Color Red Green Blue Black This wiring diagram shows only typical connections Actual wiring depends on LED Tube configuration and installation Actual no vary according to cable lengths and si...

Page 16: ... or property damage Do not use product s if cables are damaged Do not connect cables and connectors when wet or in wet area Moisture on bare connectors can cause electric shock and damage to product s Do not use product s in extreme heat environment Ensure there is sufficient airflow and use cool air circulation if required Do not drop knock or shake product s Rough handling can damage the electro...

Page 17: ...tput wires are connected with proper polarity Check Wago terminal block fuse If Indicator Lamp is on either the fuse is not present or it is blown Check if LED Engine s secondary output is working as specified Shadowing Light source covered Check for cables wires or unwanted debris covering LED light source Modules are dim Excess products connected Ensure the power supplies are not overloaded due ...

Page 18: ...0 5kg Operating Temperature 25 C to 50 C 13 F to 122 F Storage Temperature 40 C to 70 C 40 F to 158 F ARCHISHAPE Tube Ultra Slim RGB W Color Range 16 7 Million additive RGB colors White CCT 5000K Light Source 9RGB 9White 15RGB 15White 30RGB 30White Beam Angle 100 Power Input 48V DC Power Consumption typ 3 6W 6 2W 12W Weight 0 18kg 0 3kg 0 5kg Operating Temperature 25 C to 50 C 13 F to 122 F Storag...

Page 19: ... degradation is a complex function of many factors such as operating efficiency duration of continuous operation and operating conditions e g ambient temperature Because LEDs are semiconductor devices their performances are subject to inherent variability commonly found in semiconductor industry To improve consistency in performance across the same product LED manufacturers sort LEDs into bins acc...

Page 20: ...Please check for the latest updates and changes on the Traxon website 2020 TRAXON TECHNOLOGIES ALL RIGHT RESERVED Information is subject to change without prior notice www traxontechnologies com ...

Reviews: