A l l e g r o W a s h e r A C 5 0 W
M o u n t i n g G u i d e
www.traxontechnologies.com
©2020 TRAXON TECHNOLOGIES - AN OSRAM BUSINESS. ALL RIGHTS RESERVED. TRAXON™, TX CONNECT®, ARE TRADEMARKS OF TRAXON TECHNOLOGIES. U.S. PATENTS, E.U. PATENTS, JAPAN PATENTS, OTHER PATENTS PENDING. SPECIFICATIONS ARE SUBJECT TO CHANGE
WITHOUT NOTICE.
Mounting Guide
01/20 V0.4
3 of 4
5cm
(Minimum Bending Radius)
(Non-Bendable Length)
4D
D
To properly bend the cable:
•
Cable must NOT bent below the Minimum Bending Radius
Non-Bendable Length of 5cm near the connector end MUST be
adhered to.
•
Note the minimum bending radius for conductors > 1.5mm
2
.
•
Pull forces on the contact points can be avoided by bending
the wire as required.
0.8 - 1.0 Nm
0.6 - 0.7 lb ft
25mm/1”
8mm/0.3”
30mm/1.2”
8mm/0.3”
0.8 - 1.0 Nm
0.6 - 0.7 lb ft
0.8 - 1.0 Nm
0.6 - 0.7 lb ft
Avoid vertical placement of the connectors.
If vertical installation is unavoidable:
•
Add
silicone
glue on the surface of cable gland.
•
Layout the cable to have drip loop to allow water run off
the wire.
XB.AC.3106000 (for cable OD 6-10mm)
XB.AC.4006000 (for cable OD 10-14mm)
3-pin Field Installable AC Female Connector IP66
XB.AC.2303000
5-pin Field Installable AC Female Connector IP66
(for cable OD 10-14mm)
XB.AC.2302000
5-pin Field Installable AC Male Connector IP66
(for cable OD 10-14mm)
Remember to tighten cable gland after installation.
Make sure the cable gland also tighten the cable
sheath.
Applicable to Field Installable Connectors.
Silicone Glue
Silicone Glue
Do no put excessive force or
install connectors in a vibrating
environment.
30mm/1.2”
8mm/0.3”
8mm/0.3”
25mm/1”
30mm/1.2”
8mm/0.3”
8mm/0.3”
25mm/1”
10-14mm/0.4”-0.55”
10-14mm/0.4”-0.55”
6-10mm/0.24”-0.4”
10-14mm/0.4”-0.55”