Page 1: ...Allegro Tube Mono INSTALLATION GUIDE V2 0 Cover Allegro Tube Mono Cold White Allegro Tube Mono Warm White ...

Page 2: ...CATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide IG0105EN V2 0 03 20 P 2 of 19 CONTENT For your own safety and that of the product please read this installation guide carefully before beginning setup and installation SAFETY AND OPERATION 3 1 INTRODUCTION 4 2 INSTALLATION 7 3 SYSTEM CONFIGURATION 12 4 CARE AND MAINTENANCE 16 5 TECHNICAL SPECIFICATION 17 6 TROUBLESHOOTING 18 7 WARRANT...

Page 3: ...or use 5 Ensure product operates within the specified temperature range Refer to 5 TECHNICAL SPECIFICATION for more details 6 Do not attempt to open the product Not user serviceable 7 Do not use the product if any part of it or the power cables are damaged 8 Only use product for specified voltage do not exceed Refer to 5 TECHNICAL SPECIFICATION for more details 9 Always maintain connection to ensu...

Page 4: ... Tube Mono distinguishes façades walls and borders with a concentrated even radiance due to its front diffuser Its compact low profile design is available in different lengths and combined with project specific mounting options the Allegro Tube Mono is able to meet rigorous application demands For installations of varying size the Allegro Tube Mono offers flexibility and lends vitality to any proj...

Page 5: ...o Tube Mono 86 See DETAIL A Cable length From strain relief exit excluding the connector Cable length From strain relief exit excluding the connector 2P Male Input Connector 2P Female Output Connector φ15mm 0 6 φ15mm 0 6 B A D C DETAIL A with mounting bracket 50mm 1 97 80mm 3 15 80mm 3 15 52mm 2 04 B A D C Mounting bracket 260mm 700mm 1200mm 10 2 27 6 47 2 φ 6 5 m m 0 3 30mm 1 2 26 5mm 1 04 11 1mm...

Page 6: ...XON TX CONNECT ARE TRADEMARKS OF TRAXON TECHNOLOGIES U S PATENTS E U PATENTS JAPAN PATENTS OTHER PATENTS PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide IG0105EN V2 0 03 20 P 6 of 19 1 3 Packing Contents FIG 2 Packing Contents Allegro Tube Mono Mounting Bracket 2X ...

Page 7: ... The number of Allegro Tube Mono and appropriate LED Engines Any optional DMX2PWM Dimmers or DMX512 controllers to be used with the Allegro Tube Mono Distance between each Tube for thermal expansion It needs to plan mounting distances according to the mounting brackets 2 1 1 Installation Checklist 1 Prepare cables and all necessary accessories 2 Perform functional check of Allegro Tube Mono 3 Ensu...

Page 8: ...ATENTS PENDING SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide IG0105EN V2 0 03 20 P 8 of 19 2 2 Pre Installation Checks 2 2 1 Requirements of Cable Bending To reduce stress induced on Allegro Tube Mono lead cables please adhere to the Minimum Bending Radius of 24mm only allow for one time bending during installation Only allow for one time bending FIG 3 Cable Bending ...

Page 9: ...9 60mm 0 77 25mm 0 98 30mm 1 18 4mm 0 16 10mm 0 39 6 50mm 0 26 M6 or T6 Screws not included 2 2 3 Installation Sequence 1 Plan for any possible bending of cables see above 2 Measure the correct distances for Mounting Brackets 3 Connect Allegro Tube Mono with LED Engines in the daisy chain manner outlined in the Wiring Diagram P 13 to form large installations 4 Perform functional check on all Alleg...

Page 10: ...chnologies ALWAYS keep the cables protected from sharp objects and ensure no damage is generated on the cables Failure to keep Allegro Tube Mono within the operating temperature range of 30 C to 60 C 22 F to 140 F and storage temperature range of 40 C to 70 C 40 F to 158 F will void the product s warranty 1 To mount using the Mounting Bracket first affix Mounting Bracket to the installation surfac...

Page 11: ...m 1 6 5 5mm 5 Allegro Tube Mono L 630 630mm 24 8 400mm 15 7 10 30mm 6 Allegro Tube Mono L 1240 1240mm 48 8 1000mm 39 4 10 30mm L2 L3 The position of two mounting brackets must be located within L3 and please make sure that the space between mounting bracket and cable loop end should be at least 5mm clearance 5mm 5mm 4 Connect Tubes in the daisy chained manner as detailed in the Wiring Diagram Alwa...

Page 12: ...sy chain system with power and data on the same cable FIG 8 shows some typical components for the Allegro Tube Mono System FIG 8 Connection Components for Allegro Tube Mono System Optional DMX2PWM 3CH Dimmer Starter Cable TU AC 0800000 Allegro Tube Mono Starter Cable Open Wire 3m TU AC 0900000 Allegro Tube Mono Starter Cable Open Wire 10m AWG 17x 2C TU AC 1000000 Connector End Cap HLG 100H 48 LED ...

Page 13: ...9 FIG 9 Typical wiring with T Starter cable and Single Starter cable LED Engine 100W AWG 17 x 2C 300mm AWG 14 x 2C T Starter Cable Option Single Starter Cable Option T STARTER CABLE AWG 14 x 2C 0 6m Terminal block not included T Starter Cable at center 50 meters max LED Engine to last Tube IP66 CONNECTOR SEAL INDOOR OUTDOOR LED Engine 100W Starter Cable AWG 17 x 2C INDOOR OUTDOOR Mains AC Mains AC...

Page 14: ...ICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide IG0105EN V2 0 03 20 P 14 of 19 FIG 10 Allegro Tube Mono with optional DMX2PWM 3CH Dimmer Mains AC LED Engine 100W DMX2PWM Dimmer 160125 35 meters max LED Engine to last Tube INDOOR OUTDOOR Starter Cable AWG 17 x 2C 10m Controllers CONTROLLER 512 DMX Channels per output SYMPL DMX Node IP66 CONNECTOR SEAL End Cap Seal on Last Tube Conn...

Page 15: ...S ARE SUBJECT TO CHANGE WITHOUT NOTICE Installation Guide IG0105EN V2 0 03 20 P 15 of 19 FIG 11 Allegro Tube Mono with optional DMX2PWM 9CH Dimmer DMX2PWM Dimmer 160126 Mains AC LED Engine 480W 35 meters max LED Engine to last Tube INDOOR OUTDOOR Starter Cable AWG 17 x 2C 10m Controllers CONTROLLER 512 DMX Channels per output SYMPL DMX Node IP66 CONNECTOR SEAL TU AC 1000000 End Cap Seal on Last Tu...

Page 16: ...y or property damage Do not use product s if cables are damaged Do not connect cables and connectors when wet or in wet area Moisture on bare connectors can cause electric shock and damage to product s Do not use product s in extreme heat environment Ensure there is sufficient airflow and use cool air circulation if required Do not drop knock or shake product s Rough handling can damage the electr...

Page 17: ...egrades over time a term called lumen depreciation This also explains why it is nearly impossible to expect photometric performances of two LED products with different service life spans to be the same The rate of LED degradation is a complex function of many factors such as operating efficiency duration of continuous operation and operating conditions e g ambient temperature Because LEDs are semi...

Page 18: ...heck for cables wires or unwanted debris covering LED light source Modules are dim Excess products connected Ensure the power supplies are not overloaded due to an excess of products connected Flickering Incorrect power input Excess products connected Ensure the input voltage is correct Ensure the power supplies are not overloaded due to an excess of products connected If problems persist or the p...