F
INALIZING THE
I
NSTALLATION
(C
ONT
.) -
For qualified installers only!
P
AGE
17
6
Check the pilot flame
to make sure it looks
like the illustration to
the right. Adjust the
pilot flame if
necessary.
7
Let the heater burn
for fifteen minutes.
Adjust the air shutter,
if necessary, to
achieve the correct
looking flame (see
the illustration to the
right).
¥
The air shutter
adjusts the
amount of air that
mixes with the
gas before it exits
the burner holes.
It is used to fine-
tune the flame for
differences in
altitude and vent
configuration.
!
If the air shutter
is in its fully
open position, yet
the flames remain
sooty, shut off
gas to the heater
and contact your
dealer for a
remedy.
!
If the vent
configuration is
installed incorrectly
the vent may cause
the flames inside the
The pilot flame should impinge the top 3/8Ó of the
thermopile. If it does not, you may need to turn
the pilot up.
3/8Ó
Thermopile
Pilot Hood
Thermocouple
To adjust the pilot flame, remove the cover screw (and
gasket) and turn the needle valve. Clockwise lowers
the flame while counter-clockwise raises it.
PILOT ADJ
T
O
L
PI
ON
OFF
Standard
Screwdriver
Micro (1/16Ó)
Standard
Screwdriver
A
The cover screw and
gasket must be
replaced to prevent gas
from leaking
Cover Screw
Cover Screw Gasket
Needle Valve
Gas Control Valve
PILOT ADJ
VENT
HI
LO
Correct
Flames should be blue at the
base, yellow-orange on the top.
If the flames are over 12" tall or sooty
on the ends, push up on the lever.
If the flames are all blue and
short, pull down the lever.
Not Enough Air
Too Much Air
Locate the air shutter adjustment
lever behind the gas control valve.
Move it up or down until the flame
looks correct. Pushing up gives the
flame more air (making it bluer).
Pulling it down cuts air down,
making it more orange.
NOTE
: If the air control is all the
way up, yet the flames remain
sooty, shut off gas to the fireplace
and contact a qualified gas service
technician.
NOTE
: The logs must be installed correctly to
monitor the flame while adjusting the air shutter.
T
O
L
PI
ON
OFF
The flames should burn right off
the top of the burner ports (if they
are too blue, adjust the air control).
If the flames are lifting, yet the
vent configuration is correct,
contact your dealer.
Burner Pan
Burner Ports
(consists of slots
and holes)
If the flames are ghosting, yet the
vent configuration is correct,
contact your dealer.
fireplace to lift or "ghost" Ð a dangerous situation. Inspect the flames after installation to insure
proper performance. If the vent configuration is correct, yet the flames are lifting or ghosting, shut
off gas to the fireplace and contact the dealer for information on remedying the problem.
8
Turn the flame adjust knob to its highest position - the flames should be between 12" and 16".
Check the flame on low position. The flames should burn off of each burner hole. If the heater does
not work correctly, contact your dealer for a remedy.
9
Give this manual to the home owner and fully explain the operation of this heater.