Installation Notes  

 

Install The Blower First 

The blower is best installed by removing the rear access plate.  This must be done before the fireplace is 

installed.  If the fireplace has already been installed, the blowers may be installed by removing the burner 
then removing the access plates on the firebox floor.   

WARNING

Disable power to the fireplace while installing the blower (disable the service breaker).  Do not 
activate power to the fireplace until the blower kit is fully installed and grounded. 
Do not connect 110-120 VAC to the gas control valve or wiring system of this appliance. 

 

 

If installing the blowers prior to installing the fireplace (RECOMMENDED) skip the to the 
“Installation” section on page 4. 

 

Installing the Blower from Inside Firebox (not recommended) 

The fireplace is equip with a removable valve tray assembly that allows for installation and service of the 
blower after the fireplace has been installed.  To access the lower portion of the appliance: 

  Turn the gas off to the fireplace. 

  Disable AC power to the fireplace (turn off breaker) 

  Remove the glass assembly and logs (see manual). 

  Remove the burners (see manual).   

  Remove the media tray skirt. 

 

  Remove the (2) ¼” screws that secure the media tray to the grate assembly and remove the media tray.  

  

 

  Remove the (4) ¼” screws that secure the grate to the firebox (2 on the back of the firebox and 2 to the 

floor – see below). 

 

 

Remove 

Media Skirt 

Summary of Contents for ProBuilder 36CF GSB2

Page 1: ...es Inc Compatibility ProBuilder 36CF GSB2 ProBuilder 42CF GSB2 ProBuilder 36CF MV ProBuilder 42CF MV Packing List Left and Right Blower Assemblies 5 8 32 KEPS nuts use 11 32 wrench Rheostat Assembly W...

Page 2: ...control valve or wiring system of this appliance If installing the blowers prior to installing the fireplace RECOMMENDED skip the to the Installation section on page 4 Installing the Blower from Insid...

Page 3: ...iver to remove the 12 screws that secure the valve tray see below Disconnect the gas line from the service shutoff valve below the firebox see below Disconnect electrical connections to the valve tray...

Page 4: ...of the fireplace see below 3 Attach the wire harness to the blower assemblies The BLUE connectors will attach to the left blower and the RED will attach to the right see below NOTE Left and Right are...

Page 5: ...Page 5 of 8 17602032 Printed 8 20 18 Travis Industries Inc 6 Take the 2 green wires connected to the blower brackets and place them both over the center stud in the cavity under the fireplace Use 1 of...

Page 6: ...the blower assemblies do not overtighten The blower assemblies should be oriented so the motors are in the middle see picture below 8 The portion of the installation that is performed through the rear...

Page 7: ...8 20 18 Travis Industries Inc 10 Attach the rheostat asembly to the back of the dashboard as shown below Secure using 2 of the 8 32 KEPS nuts 11 Find the wires maked Rheostat on the wire harness and a...