Travis Industries GreenSmart SKU 99300698 (LP) Instalation Instructions Download Page 8

 

GreenSmart™ Remote – Export Version 

SKU 99300699 (NG)            SKU 99300698 (LP) 

 

Page 8 of 15 

9/25/09  -  17601590 

© Travis Industries, Inc.  

16 

Pull the “RECEIVER” connector through the control panel and attach to the receiver (see Figure 
21).  Then attach the receiver to the control panel with the two #8 machine screws (see Figure 22). 

 

Figure 21 

 

Figure 22 

17 

Place batteries into the receiver and transmitter (see Figure 23).  Calibrate the receiver to the 
transmitter (see Figure 24 - use a paperclip to press the “PRG” button, let it beep, then press any 
button on the transmitter – the receiver should beep 5 times – see the operating instructions for 
further details). 

 

Figure 23 

 

Figure 24 

18 

Place the receiver coverplate (and switch) over the receiver (see Figure 25) and attach with the 
two screws included with the receiver (see Figure 26) 

 

Figure 25 

 

Figure 26 

Summary of Contents for GreenSmart SKU 99300698 (LP)

Page 1: ...oducts 564 SS GS 864 TRV GS 864 ST GS Packing List Transmitter with 3 AAA Batteries Receiver with Cover Plate Switch LP or NG Stepper Motor with screws and label attaches to Valve Wire Harness 2 8 x Machine Screws 2 Wire Ties Torx T 20 Wrench Wall Mount for placing the transmitter on a wall 2 Drywall anchors for wall mount 2 8 x 3 8 Type B Screws F Transmitter Receiver Stepper Motor Transmitter Wa...

Page 2: ...ze yourself with the updated wiring diagram see the illustration below CN4 CN3 PILOT SENSOR SPARK ROD DIGITAL FIREPLACE BURNER CONTROL CN2 GROUND VALVE COMMAND POWER CN1 DIAGNOSTIC CN0 GREENSMART PILOT CONTINUOUS PILOT White Black Yellow Green Orange VALVE IPI CPI TOP 4 AA Batteries Remote Receiver STEPPER MOTOR BURNER CONTROL RECEIVER Comfort Control Valve Green Pilot Sensor Spark Rod Pilot Groun...

Page 3: ... 564 Installation on other models is similar take care to prevent any hot or moving parts from contacting any wiring 1 Remove the concealment cover if applicable see Figure 1 Figure 1 2 Unscrew the four screws holding the control cover in place see Figure 2 Carefully remove the control cover see Figure 3 Figure 2 Figure 3 3 Unplug the ac adapter from the receptacle see Figure 4 You can leave the a...

Page 4: ...control valve are fragile Take care when removing the molex connector to not pull or damage the wires or tabs Figure 5 5 Disconnect the two leads on the back of the control panel for the IPI CPI switch continuous pilot greensmart pilot see Figure 6 Figure 6 6 Disconnect the comfort control valve connection see Figure 7 Disconnect the burner control connector from the fireplace burner control see F...

Page 5: ... see Figure 10 Figure 9 Figure 10 8 The control panel may have plastic wire locks attached to the back see Figure 11 Un hook the wires from the wire locks and remove the wiring harness plate battery holder and ac adapter see Figure 12 These items may be discarded keep the batteries for the receiver Figure 11 Figure 12 9 Use the included torx wrench to remove the stock regulator see Figure 13 These...

Page 6: ...as control valve see Figure 14 MAKE SURE IT IS CORRECTLY ORIENTED Secure using the screws included with the motor see Figure 15 tighten to 25 Lb inches Leak test this area after installation to verify proper installation Figure 14 Figure 15 11 Place the GreenSmart wiring harness in front of the fireplace noting the position of each connector 12 Attach the wiring harness to the burner control see F...

Page 7: ...ttach the blue and white wires to the IPI CPI switch see Figure 18 Connect the wiring harness to the stepper motor see Figure 19 Figure 18 Figure 19 14 Attach the wiring harness to the comfort control valve connection see Figure 20 Figure 20 15 Plug the AC Adapter on the wiring harness into the receptacle on the fireplace ...

Page 8: ...Figure 21 Figure 22 17 Place batteries into the receiver and transmitter see Figure 23 Calibrate the receiver to the transmitter see Figure 24 use a paperclip to press the PRG button let it beep then press any button on the transmitter the receiver should beep 5 times see the operating instructions for further details Figure 23 Figure 24 18 Place the receiver coverplate and switch over the receive...

Page 9: ...ll wiring from contacting any hot or moving components Re attach the control panel see Figure 28 and shroud see Figure 1 Figure 27 Figure 28 20 A wall mount is included with this kit for the remote It may be mounted to the wall for easy access and storage Use the included drywall anchors and screws to secure it to the wall see Figure 29 Figure 29 23 Restore power to the fireplace and test operatio...

Page 10: ... AAA Battery AAA Battery AAA Battery Figure 30 Receiver Battery Installation Install four AA batteries into the receiver see Figure 31 You can use the batteries from the battery backup tray on the appliance See the installation instructions for details These batteries control the comfort control and act as a power backup in case the household AC current goes out A A B a t t e r y A A B a t t e r y...

Page 11: ...tended period of time you may need to re synchronize the remote Direct Fireplace Operation The fireplace may be directly operated from the receiver The three positions are below see Figure 33 ON Fireplace burner turns on regardless of transmitter settings OFF Fireplace burner turns off regardless of transmitter settings REMOTE Fireplace is controlled by the transmitter ON REMOTE OFF PRG Figure 33 ...

Page 12: ...r main sections see Figure 34 ON F MAX Thermostat Display Room Temperature Display Read Out Thermostat Setting Function etc Mode Display Flame Height Comfort Control Figure 34 Listen for the Beep Each time you press a button on the transmitter that controls the fireplace a beep will come from the fireplace When you change thermostat target settings the fireplace will not beep NOTE When the receive...

Page 13: ...ll be adjusted up or down to allow operation without turning the burner on and off also called smart modulation To adjust the target temperature press the up and down buttons until a suitable temperature is achieved ON F When in standard thermostat setting the word ON will appear here This is the target temperature on the read out Use the up or down buttons to adjust the target temperature Figure ...

Page 14: ...isplay the 7 settings from OFF to HI for full on NOTE Flame height may not be adjusted if operating in Smart Thermostat setting OFF F When in flame height mode this icon will appear darkened MAX This is the flame height read out Use the up or down buttons to adjust the flame height 7 settings High Medium Off Figure 40 Comfort Control rear burner The comfort control rear burner may be turned on and...

Page 15: ...eries into the receiver when this occurs see Receiver Battery Installation on page 10 In applications where the appliance is required to provide heat we recommend replacing the batteries before each heating season Child Proof Feature The child proof feature disables the control buttons preventing un wanted use of the remote Press both the MODE and UP buttons simultaneously to turn this feature on ...

Reviews: