Diffuser Plate Adjustment 

Certain vent configurations require the diffuser plate to be adjusted (refer to the approved vent 
configuration charts for details). Position # 1 is stock (bent).  Position # 2 is flattened.  See the directions 
below to change the diffuser to position #2. 

Back Wall of Firebox

Firebox Roof

Remove the exhaust 
restrictor.

1/4" Nutdriver

Remove the diffuser.

1/4" Nutdriver

Secure the flattened 
diffuser plate with the 
screws removed earlier.

Replace the exhaust 
restrictor (see “Exhaust 
Restrictor Adjustment” 
for restrictor settings).

Bend the round portion of the 
diffuser so it is flat (position # 2).

Before (Stock - Position # 1)

After (Position # 2)

DIFFUSER SIDE VIEW

 

Summary of Contents for GreenSmart 564 GS

Page 1: ...call gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualifie...

Page 2: ...ation requirements for the 564 GS fireplace For operating and maintenance instructions refer to the 564 GS Owner s Manual part 100 01223 Listing Details This appliance was listed by SAI Global to AS 4...

Page 3: ...e Considerations 21 Approved Vent 22 Vent Installation 22 Approved Vent Configurations 23 Restrictor Position 23 Exhaust Restrictor Adjustment 23 Intake Restrictor Adjustment 24 Diffuser Plate Adjustm...

Page 4: ...gas NG or propane LP Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard Direct questions about the type of fuel used to your dealer Check the l...

Page 5: ...he fiber logs become damaged replace with Travis Industries log set Do not throw this manual away This manual has important operating and maintenance instructions that you will need at a later time Al...

Page 6: ...Input Per Hour 20 500 20 500 Maximum Megajoules MJ Input Per Hour 21 6 21 6 Heating capacity will vary with floor plan insulation and outside temperature Efficiency rating is a product thermal effici...

Page 7: ...imum Framing Dimensions Drywall Top Vent Configuration Rear Vent Configuration See the section Gas Line Installation Side Wall See Optional Non Combustible Facing Drywall See Optional Non Combustible...

Page 8: ...secure the standoff Bend the standoff in the numbered sequence shown above Remove the screw below the standoff b 1 2 3 c The standoffs are shipped in the flat position Make sure to follow the instruc...

Page 9: ...e diffuser when changing the vent configuration Converting the Fireplace to Top Vent Configuration Remove the 4 screws securing the outer flue assembly Place the screws and assembly aside NOTE Use a m...

Page 10: ...he rear facing exhaust port with the same screws Verify the gasket on the intake cover plate is in place then attach it to the rear of the fireplace using the screws removed earlier Verify the gasket...

Page 11: ...r non combustible surface not on linoleum or carpet This heater may be placed in a bedroom Please be aware of the large amount of heat this appliance produces when determining a location Clearances Wh...

Page 12: ...1 25mm to the sides 1 25mm below and 4 102mm above the vent to combustibles Included Firestop required Part 250 00747 Center of Rear Vent HINT place the fireplace so the center line is at least 5 127m...

Page 13: ...e to a position to the left rear of the fireplace 36 1 2 927mm 33 1 2 851mm 16 1 2 419mm WARNING A cut out for the gas line may be required on the framing See the dimensions under Gas Line Connection...

Page 14: ...r tab out 90 use a screwdriver if necessary Fireplace Drywall Framing Nailing Bracket TOP VIEW 1 2 13mm Drywall 5 8 0 625mm Drywall There are four nailing brackets on the front of the fireplace Follow...

Page 15: ...lation uses the framing dimensions shown in the illustration below NOTE all clearances still apply 7 178mm Approximate varies due to vent installation 44 1 2 Min 1130mm Minimum 1 2 13mm Clearance NOTE...

Page 16: ...Industries 4090709 100 01222_000 Corner Installations Top Vent Configuration A typical 45 installation uses the framing dimensions shown in the illustration below NOTE all clearances still apply 14 1...

Page 17: ...ther for natural gas or for propane but not for both Check the sticker on the top of the gas control valve to make sure the correct fuel is used Gas Line Connection Installation must be performed by a...

Page 18: ...er plate has a 7 8 0875mm diameter hole covered with a push plug in line with the gas inlet on the gas control valve By rotating the plate 180 the hole may be re located You may also secure the plate...

Page 19: ...hut off prior to working on any electrical lines The appliance when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical...

Page 20: ...to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Note When using a GreenSmart remote use the receiver for on off operation do not use a wall switch or...

Page 21: ...s use the high wind termination if available from the vent manufacturer Vent Clearances The vent must maintain the required clearance to combustible materials to prevent a fire Do not fill air spaces...

Page 22: ...for details Always use the high wind cap or high wind sconce cap part 58DVA HSCH or 46DVA HSCH Installation instructions for Simpson Dura Vent may be found at www duravent com 6 5 8 168mm Diameter Ven...

Page 23: ...ptable vent configurations detail the correct vent restrictor positions Exhaust Restrictor Adjustment If the diffuser is required to be in position 2 you may wish to adjust the diffuser while the exha...

Page 24: ...Travis Industries 4090709 100 01222_000 Intake Restrictor Adjustment Loosen the two screws holding the intake restrictor in place 1 4 Socket Slide the restrictor down to the lower position and tighten...

Page 25: ...on 2 is flattened See the directions below to change the diffuser to position 2 Back Wall of Firebox Firebox Roof Remove the exhaust restrictor 1 4 Nutdriver Remove the diffuser 1 4 Nutdriver Secure t...

Page 26: ...5 Elbow Termination See the charts below to determine maximum vent 3 feet 915mm 0 feet mm 0 feet mm 4 max 610mm Exhaust Restrictor 0 stock Intake Restrictor 1 stock Diffuser Position 1 stock Vent with...

Page 27: ...et 1 5 m 10 feet 3 m 5 feet 1 5 m 10 feet 3 m 0 feet 15 feet 4 5 m 20 max 6 m 10 feet 3 m 15 feet 4 5 m 15 feet 4 5 m 20 max 6 m 10 feet 3 m 15 feet 4 5 m 22 max 6 7 m 22 max 6 7 m Exhaust Restrictor...

Page 28: ...t 3m 0 feet 15 feet 4 5m 20 max 6m 10 feet 3m 15 feet 4 5m 15 feet 4 5m 20 max 6m 10 feet 3m 15 feet 4 5m 40 max 12m Exhaust Restrictor 6 Intake Restrictor 2 Diffuser Position 2 25 feet 7 5m 30 feet 9...

Page 29: ...et 20 feet 6m 20 feet 6m 5 feet 1 5m 10 feet 3m 5 feet 1 5m 10 feet 3m 0 feet 15 feet 4 5m 20 max 6m 10 feet 3m 15 feet 4 5m 15 feet 4 5m 20 max 6m 10 feet 3m 15 feet 4 5m 21 max 6 4m 21 max 6 4m Exha...

Page 30: ...m 10 feet 3m 5 feet 1 5m 10 feet 3m 0 feet 15 feet 4 5m 20 max 6m 10 feet 3m 15 feet 4 5m 15 feet 4 5m 20 max 6m 10 feet 3m 15 feet 4 5m 40 max 12m Exhaust Restrictor 6 Intake Restrictor 2 Diffuser Po...

Page 31: ...with local installation codes and the requirements of the gas supplier G Minimum 48 1219mm clearance from any adjacent building H Minimum 84 2134mm clearance above any grade when adjacent to public wa...

Page 32: ...ring the fireplace must be raised so the base of the unit is above the carpet surface or flooring material Floor Mounted Fireplaces Raised Fireplaces A hearth is not required when the fireplace is rai...

Page 33: ...ce Tile or other non combustible facing may be placed on the front of the fireplace see Facing Overview on page 34 for further details Drywall Installation Drywall Installation Drywall may be installe...

Page 34: ...up to this location 1 25mm above the base of the fireplace The fireplace may be raised to accommodate thicker hearth materials Masonry Line Hearth Line Tile Line Tile Line Masonry Line Tile Line Mason...

Page 35: ...air Raised Fireplaces Facing is installed 1 maximum 25mm above the base of the fireplace Facing is installed to this edge of the fireplace FRONT VIEW Tile Line Tile Line Hearth Line Tile Line 27 3 4...

Page 36: ...ce Note how the facing extends 1 25mm above the base of the fireplace 1 25mm Fireplace Support Floor Drywall Tile or other facing under 1 25mm thick Face Floor Max 1 25mm Hearth note how it extends un...

Page 37: ...Drywall Fireplace Drywall Framing Nailing Bracket Masonry TOP VIEW Protruding Masonry Fireplace Drywall or cement board etc Framing NOTE The nailing brackets are not used for this type of installatio...

Page 38: ...500674 The template helps locate and support the masonry as it being installed Masonry Line Hearth Line Drywall Floor Mounted Fireplaces or Raised Hearths Build the hearth 1 max 25mm above the base of...

Page 39: ...The masonry extends 1 25mm above the base of the fireplace 1 25mm Fireplace Support Floor Floor Mounted Fireplace with Hearth SIDE OF FIREPLACE Drywall Masonry or other non combustible over 1 25mm thi...

Page 40: ...3 4 0 75mm or less they may be placed directly to the side but not in front of the fireplace Non combustible mantel columns do not have a minimum clearance 38 1 2 978mm 12 305mm Maximum Non Combustibl...

Page 41: ...2mm EXTERIOR WALLS When installed with a 2x4 51mm X 102mm exterior wall the termination may not fit flush against the exterior wall You may wish to place framing around the termination to fill the gap...

Page 42: ...Section Firestop NOTE FOR 2 x 4 51mm X 102mm EXTERIOR WALLS When installed with a 2x4 51mm X 102mm exterior wall the termination may not fit flush against the exterior wall You may wish to place frami...

Page 43: ...se a cloth or paper towel 4 Install the four AA batteries included in the owner s pack into battery holder see the illustration below The AA batteries act as a power backup in case the household AC po...

Page 44: ...to use pliers to adjust the front air shutter Typically the front air shutter is fully closed left on NG fully open right on LP 10 Turn the flame adjust knob to its highest position the flames should...

Page 45: ...s Open the four latches holding the glass frame in place start with the bottom follow the directions shown to the right a Lift the glass frame up and pull it forward to remove b Re Attaching the Glass...

Page 46: ...ed 1 4 turn when it is disengaged Follow the directions below to re install the latch if it becomes loose Top of Firebox Hold the latch at an angle and insert it into the slot on the glass frame ancho...

Page 47: ...llation for qualified installers only 47 Travis Industries 4090709 100 01222_000 Log Set Installation Log Set Overview When installed the logs should appear as shown below Rear Log Left Log Right Twig...

Page 48: ...only Travis Industries 4090709 100 01222_000 Rear Log Installation Place the rear log on the grate and slide it all the way back until the log contacts the end brackets on the grate The rear log has...

Page 49: ...ualified installers only 49 Travis Industries 4090709 100 01222_000 Right Log Installation Note how the right side of the log rests on the burner but does not cover any burner holes The right log has...

Page 50: ...or qualified installers only Travis Industries 4090709 100 01222_000 Left Log Installation The left log has a groove that fits over the grate Note how the right side of the log rests on the burner but...

Page 51: ...ion for qualified installers only 51 Travis Industries 4090709 100 01222_000 Left Twig Installation This hole fits over the pin on the rear log The left twig should be positioned so the front edge con...

Page 52: ...lation for qualified installers only Travis Industries 4090709 100 01222_000 Right Twig Installation The right twig has two holes for the pins on the rear and right log When in place the right twig wi...

Page 53: ...rs only 53 Travis Industries 4090709 100 01222_000 Ember Installation A bag of embers is provided to further enhance the firebox Place the embers on the firebox floor and on the burner Do not place em...

Page 54: ...uctions Install the conversion kit prior to installing the gas line to ensure proper gas use 1 Remove the glass see page 43 Remove the logs and embers if installed page 47 2 Remove the burner see illu...

Page 55: ...ce in so the orifice protrudes 15 16 24mm indicating full insertion d Look here for the orifice identification Apply thread sealant to the LP orifices prior to installation Use the chart below to iden...

Page 56: ...rd the screws see a below holding the stock regulator in place see b below Remove the stock regulator and gasket see c below Place the LP regulator in place making sure the pre fitted gasket see c bel...

Page 57: ...the fireplace to the correct configuration Remove the grate replace after fireback installation 1 4 Nutdriver Remove and discard the hearth plate Loosen this screw and slide the bracket up Place the...

Page 58: ...need to press on the grill to get the tab over the bushing this prevents the grill from accidentally falling off Bend the tab outward on both sides This is the end stop for the lower grill it allows...

Page 59: ...Optional Equipment for qualified installers only 59 Travis Industries 4090709 100 01222_000...

Page 60: ...ontalTermination 42 Installation Options 6 Installation Overview 7 Intake Restrictor Adjustment 24 Listing Details 2 Log Set Installation 47 LP Conversion Instructions 54 Mantel Requirements 40 Minimu...

Reviews: