Page 10
17602010 - 12/15/17
Push Auger Motor Removal
Make sure the stove has fully cooled (approximately 25 minutes) before conducting service. Unplug the
stove to prevent electrical shock.
1. Remove the rear panel (see section “Rear Panel Removal”).
2. The push auger motor is the motor that is directly above the air intake of the stove and is facing horizontally.
3. Use a 3/16” Allan wrench to loosen the retaining screw. If you only remove the screw enough to allow the
shaft of the motor to become free, the collar will stay in place making for easier re installation of the auger
motor.
Retaining
Screw
“D” Shaped
part of Shaft
Collar
Auger
Motor
Auger
Shaft