Troubleshooting Steps
2 - 3
© 1998 Travis Industries, Inc.
93508201
011202
Stove Cleaning (continued)
Clean the Vertical Exhaust Duct
The following models have vertical exhaust ducts welded in place.
Heritage Bay PS serial # below 211650
Heritage Bay PI serial # below 410650
Avanti PS serial # below 121700
Avanti PI serial # below 320525
To clean, follow the directions below.
Use a hammer to tap against the
fireback in front of the vertical exhaust
ducts (not too hard). This should
dislodge loose flyash.
NOTE:
If the flyash does not dislodge, use a
bottle brush or other device to scrape
the flyash from the ducts.
Vertical Exhaust
Duct
Remove the
flyash by
removing the
ash trap doors
and sweeping
into the
ashpan.
More recent models use the cast-iron fireback as the front of the vertical exhaust duct. To clean, follow the directions
below.
Remove both
refractory side clips.
Remove the
refractory.
Clean this area
behind where the
refractory rests
(both sides).
Remove these doors to
remove fallen flyash and
soot (see ÒBi-Weekly
Maintenance for detailsÓ)