Tempest 24v Torch Transformer 

Sku# 94800829 

 

Page 2 of 4 

17602011 – Printed 2/15/18 

© Travis Industries, Inc. 

Dimensions 

 

 

 

Mounting Requirements 

  Transformer weights approximately 12.5 lbs.  Make sure mounting location provides 

sufficient support. 

  Transformer is rated for damp locations.   

  Do not place transformer where it will become submerged.   

  We suggest placing the transformer out of direct contact with the elements (rain, snow, 

sun, etc.) to extend longevity. 

  Consult your local building department for requirements in your area pertaining to 

mounting and installation of this transformer. 

 

 

5-1/8"

4-1/2"

10-1/4"

Knock-Outs for Strain Reliefs 
(both sides and bottom)

TOP

Mounting Holes

Summary of Contents for 94800829

Page 1: ...t 0 500 kVA The transformer will power up to 4 torch heads The maximum number varies depending upon the total length of cable attached between the transformer and torches See the torch manual for additional details Packing List Transformer 2 Strain Reliefs Wiring Diagram 120V Wiring Diagram 240V Transformer Junction Box Black White Grounding Post Green H2H2 H4H4 H1H1 H3H3 X2X2 X3X3 X4X4 X1X1 To 24...

Page 2: ...ort Transformer is rated for damp locations Do not place transformer where it will become submerged We suggest placing the transformer out of direct contact with the elements rain snow sun etc to extend longevity Consult your local building department for requirements in your area pertaining to mounting and installation of this transformer 5 1 8 4 1 2 10 1 4 Knock Outs for Strain Reliefs both side...

Page 3: ... and outgoing circuits Installation should only done by a qualified electrician or installer consult local codes Use suitable connectors when wiring the transformer silicone filled wire nuts The torches can be Daisy Chained together see Example A below or each torch can be a home run back to the transformer see Example B below Example A Example B Polarity must be maintained in all multiple torch i...

Page 4: ...ng a single 24VAC transformer it is important that the polarity between the torches are connected in parallel all white wires connected together and all white blue stripe wires connected together Polarity between the torches and the transformer does not matter White White Blue White White Blue 24V AC Transformer White White Blue White White Blue 24V AC Transformer Correct Incorrect WRONG DO NOT AL...