Travis Industries 94800829 Quick Start Manual Download Page 1

 

Tempest 24v Torch Transformer 

Sku# 94800829 

 

Page 1 of 4 

17602011 – Printed 2/15/18 

© Travis Industries, Inc. 

 

 

Hazardous Voltage can shock, burn, or cause death.  Disconnect all input power before 

installing or maintaining this equipment. 

Compatibility 

This transformer is designed for the Tempest 24v Torch (NG or LP).  It is not designed for 
2017 (or earlier) Tempest 120v torches. 

This transformer is rated at 0.500 kVA.  The transformer will power up to 4 torch heads.  The 
maximum number varies depending upon the total length of cable attached between the 
transformer and torches.  See the torch manual for additional details. 

Packing List

 

 Transformer 

  (2) Strain Reliefs 

 

Wiring Diagram 120V 

 

Wiring Diagram 240V 

 

 

Transformer Junction Box

Black

White

Grounding Post

Green

H2H2
H4H4

H1H1

H3H3

X2X2

X3X3

X4X4

X1X1

To 24V Tempest 

Torch(es)

120V POWER IN

Romex Clamps

H2H2

H4H4

H1H1

H3H3

Transformer Junction Box

Hot

Hot

Grounding Post

Ground

X2X2

X3X3

X4X4

X1X1

To 24V Tempest 

Torch(es)

240V POWER IN

Romex Clamps

Summary of Contents for 94800829

Page 1: ...t 0 500 kVA The transformer will power up to 4 torch heads The maximum number varies depending upon the total length of cable attached between the transformer and torches See the torch manual for additional details Packing List Transformer 2 Strain Reliefs Wiring Diagram 120V Wiring Diagram 240V Transformer Junction Box Black White Grounding Post Green H2H2 H4H4 H1H1 H3H3 X2X2 X3X3 X4X4 X1X1 To 24...

Page 2: ...ort Transformer is rated for damp locations Do not place transformer where it will become submerged We suggest placing the transformer out of direct contact with the elements rain snow sun etc to extend longevity Consult your local building department for requirements in your area pertaining to mounting and installation of this transformer 5 1 8 4 1 2 10 1 4 Knock Outs for Strain Reliefs both side...

Page 3: ... and outgoing circuits Installation should only done by a qualified electrician or installer consult local codes Use suitable connectors when wiring the transformer silicone filled wire nuts The torches can be Daisy Chained together see Example A below or each torch can be a home run back to the transformer see Example B below Example A Example B Polarity must be maintained in all multiple torch i...

Page 4: ...ng a single 24VAC transformer it is important that the polarity between the torches are connected in parallel all white wires connected together and all white blue stripe wires connected together Polarity between the torches and the transformer does not matter White White Blue White White Blue 24V AC Transformer White White Blue White White Blue 24V AC Transformer Correct Incorrect WRONG DO NOT AL...