Electrical Connection
•
The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified
installer and must meet all local codes.
•
Make sure the household breaker is shut off prior to working on any electrical lines.
•
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
•
The electrical line must be a min. 14 gauge, and supply 120 Volts, 60 Hz, and 5.7 Amps.
•
Route the electrical connection through the junction box cover plate and attach to the hookup wires
pictured below.
Caution
:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause
improper and dangerous operation.
Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace.