Travis Industries 864 Clean Face GSR2 Cheat Sheet Download Page 2

 

864 Cleanface GSR2 - Cheat Sheet 

 

Page 2 of 2 

17601834 

Printed 11/22/16 

GreenSmart™ 2 

This heater has GreenSmart™ 2 components from SIT.  These components function in a near identical 
fashion to the previous GreenSmart™ 1 components.  The primary differences are: 

• The accent light now has dimming capability built into the remote. 

• The pilot may be switched from intermittent (IPI) to standing pilot from the remote. 

Refer to the owner’s manual for full details. 

Remote Control / Pilot Warnings 

 

Installing batteries in the battery holder or connecting the appliance to power may 
automatically initiate the CPI pilot mode, resulting in a lit pilot flame. Do not place 
combustibles in the firebox. 

KEEP BATTERIES AND COVER  

INSTALLED AT ALL TIMES 

The remote control system requires the batteries and battery cover to remain 
in place at all times. Once the batteries or cover are removed, the system may 
re-start in standing pilot mode. If this occurs when the heater is in Remote 
Mode, you will not be able to turn the heater off manually from the battery box. 

If you need to replace dead batteries, make sure to 

turn the appliance off

 

before removing the batteries.   

NOTE

: If the batteries go dead, the system will operate normally as long as 

household power is present.

 

Installation Warnings 

 

Install Insulation when Converting to Rear Vent Configuration

  The insulation is 

only used for rear vent configurations.  Failure to install the insulation will create a safety 
hazard. 

 

3” (77mm) Clearance Above Vent when Rear Vented

  See manual for details. 

 

Top Vent vs. Rear Vent

  Depending upon top or rear vent configuration, maximum vent 

configuration may change.  See installation manual for details. 

 

May Use 6-5/8” (169mm) Vent in Top Vent Configuration

  See manual for details. 