44
Safety
Label
© Travis Industries
4140811
100-01340
Safety Label
The safety (listing) label is attached to the operating tag (chained to the heater near the gas control
valve). A copy is shown below.
Report No. G100518003PRT
-001
Control No. 4000515
V
e
nted Gas Fireplace Heater
430 GSR2
Tested to:
ANSI Z21.88-2014/CSA
2.33-2014 “V
ented Gas Fireplace Heater”, CGA
2.17-M91 (R2009) “Gas Burning
Heating
Appliances for Manufactured Homes”, and CSA
P
.4.1-09 T
esting method for measuring annual fireplace
efficiency
.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,
ANSI Z223.1/NFP
A 54, or Natural Gas and Propane Installation Codes, CSA
B149.1.
This appliance must be installed in accordance with the current Standard CAN/CSA
Z240 MH, Mobile Housing,
in Canada or with the Manufactured Home Constructions and Safety Standard, T
itle 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable,
ANSI/NCSBCS
A225.1/NFP
A 501A, Manufactured Home
Installation Standard.
This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired, the optional factory conversion kit must be used. Part No. 250-02863 register kit may be used.
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes. See owner
’s
manual for details. This appliance is not convertible for use with other gases, unless a
certified kit is used.
For OEM installation in a manufactured home (USA) only or mobile home only
.
This vented gas fireplace heater is not for use with air filters.
Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.
This appliance must be properly connected to a venting system in accordance with the manufacturer
’s
installation instructions. Use only approved co-linear direct vent system to vent this appliance to the exterior
.
See owner
’s
manual for approved brands of venting.
If the vent-air intake system is disconnected for servicing or any other reason, it must be resealed and / or reinstalled.
W
ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to the owner
’s
information manual provided with this appliance. For assistance or additional
information consult a qualified installer
, service agency or the gas supplier
.
VENTED GAS FIREPLACE HEA
T
ER - NOT FOR USE WITH SOLID FUEL
Minimum Clearances to Combustibles
Side of Insert to
Adjacent W
all
Hearth Depth Hearth to Sides of Insert
5” (127mm)
1.75” (45mm)
0” (0mm)
Base of Insert to Mantel Base of Insert to T
op Facing
Flue V
ent
Enclosure Clearances
See Owner
’s
Manual
See Owner
’s
Manual
See Owner
’s
Manual
See Owner
’s
Manual
FAN TYPE VENTED CIRCULA
TOR
Blower Electrical Rating: 120 V
AC, 1.8
Amps, 60 Hz
Part No. 228-10123 / 228-10124 fan or blower assembly may be used
Minimum Inlet Pressure (inches W
.C.)
Maximum Inlet Pressure (inches W
.C.)
Manifold Pressure on “HI” (inches W
.C.)
L.P
.
11
”
13”
11
”
N.G. 5.5”
7”
3.5”
Input Rate on “HI” (BTU/Hr)
Input Rate on “LO” (BTU/Hr)
Orifice Size - Front (DMS)
Orifice Size - Rear (DMS)
L.P
.
31,000
7,702
1.2mm
1.2mm
N.G. 31,000 11
,241
#48
#50
This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4,500 feet (0-1370m).
For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed.
See owner
’s
manual for information on making these changes.
2015
2016
2014
Feb.
Mar
.
Jan.
May
Jun.
Apr
.
Aug.
Sep.
Jul.
Nov
.
Dec.
Oct.
MANUF
ACTURE DA
TE:
W
ARNING: Failure to install this appliance per the manufacturer
’s
instructions or failure to use only parts
specifically approved with this appliance may result in property damage or personal injury
.
12521 Harbour Reach Drive
Mukilteo, W
A
98275
Manufactured by:
www
.travisproducts.com
CAUTION:
Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be done by a licensed or qualified service person.
1053