![Travis Industries 31 DVI GSB2 Owner'S Manual Download Page 11](http://html.mh-extra.com/html/travis-industries/31-dvi-gsb2/31-dvi-gsb2_owners-manual_1153988011.webp)
Installation (for qualified installers only)
11
© Travis Industries
4140813
100-01296
Clearances
Due to the high temperature of the heater, it should be located out of traffic and away from furniture
and draperies.
Minimum
Clearances
k Sidewall to Insert
4-1/2"
115mm
l Side Facing
(non-combustible)
4-1/2"
115mm
m Top Facing*
(non-combustible)
35"
889mm
n Mantel*
(combustible or
non-combustible)
35"
889mm
x Hearth Extension
(3-Piece Panel)
1-1/4"
32mm
x Hearth Extension
(1-Piece Panel)
0"
0mm
Mantel Clearances
The maximum mantel depth is 12” (305mm).
NOTE:
The combustible area above the facing must not protrude more than 3/4" (20mm) from
the facing. If it does, it is considered a mantel and must meet the mantel requirements listed in this
manual.
Modifying the Face Connector for Discovery, Rosario, and Artisan Faces
The Discovery, Rosario, and Artisan face require re-positioning of the face connector. See the
directions below for details.
Side
Wall
Combustible or Non-Combustible Mantel
Combustible Top Facing
Non-Combustible
Facing
l
k
x
n
m
Face Connector
Bracket
Remove the face connector bracket
from the heater (on both sides).
Re-attach the face connector to the
heater using the forward mounting holes.