VII. g-ADJUSTING THERMOSTAT SET POINT HIGH:
This parameter sets the high point of the desired cabinet temperature range. Typically, Quick Chillers will range from 31°F
to 35°F. This parameter is preset at the factory and does not have to be adjusted unless the customer chooses to do so.
Note: Set Point Low and Set Point High cannot be set to the same temperature. There must be at least 1-2 degree differ-
ence between the two settings.
Follow the instructions to enter the customer access code on page 8. When the control
display reads Thermostat Set Point High. Press the set button .
Use the arrow keys to adjust the temperature to your desired setting.
When the display shows the temperature you want press the set button .
The display will then read Thermostat Set Point High.
You can use the up or down arrow keys to scroll to the next parameter .
or press the alarm cancel button to exit
.
VII. MICROPROCESSOR CONTROL (cont’d)
-9-
Listed below are the available parameters in the order they appear, using the down arrow key on the controller. You can
use either the up or down arrow keys to scroll through the options.
Thermostat Set Point High
Defrost Lockout 3
Thermostat Set Point Low
Defrost Lockout 4
Temperature Scale
Dew Point Compensation Factor
Time
(24-hour
clock)
Room
Temperature
Offset
Date
(month-day-year)
Audible
Alarm
Style
Daylight
Savings
Cabinet
Air
Sensor
Temp
Start Manual Defrost
Evaporator Coil Sensor Temp
Defrost
Lockout
1
Discharge
Line
Sen
sor
Temp
Defrost Lockout 2
VII. f-SERVICE PARAMETERS:
SET
SET
)
)
)