![Traulsen KROGER RBC100 Service Manual Download Page 8](http://html1.mh-extra.com/html/traulsen/kroger-rbc100/kroger-rbc100_service-manual_1153110008.webp)
1. Access the control boardand/or printers by
removing four (4) thumb screws & control cover
(see fig. 1).
2. Remove the control board (see page 5) and/or
printers (see page 5 and 6) which might be
effected moisture or grease.
3.
Spray any electrical contacts (see fig. 2) which
exhibit evidence of grease or water damage
(indicated by a green color, see inset) with a
commercial contact cleaner. This will dislodge
the contamination.
5.
Wipe away any debris or excess contamination
using a cotton swab. Allow adequate time to dry.
6. Reassemble the control in reverse order.
Repairing Moisture Damage
7
TRAULSEN RBC50, RBC100 & RBC200 BLAST CHILLER BASIC SERVICE GUIDE
Fig. 1
Fig. 2
WARNING
DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND
FOLLOW PROPER LOCKOUT/TAGOUT PROCEDURES.