5. General Operation 

The keypad is used to supervise and control Roboguards and to report activity 
audibly, visually and electronically. The keypad monitors and supervises up to 
four Roboguards. If an intruder is detected the speaker will beep the number 
of the zone i.e. zone one, one beep, zone three, three beeps etc; the 
corresponding LED will flash and the selected output switch will activate. 
 
The keypad will respond to the remotes in all modes of operation. 
 

5.1 GREEN Zone LED 
(zone control and intruder detection) 

Each of the keypad zones can be individually switched on or off. Switching 
the zone off does NOT disable the supervision or the tamper monitoring. If the 
green led for the zone is OFF then the zone is disabled. If it is ON then the 
zone is ON and not triggered. If it is FLASHING then the zone is ON and has 
been triggered. Pushing the zone button will change the state of the led from 
OFF to ON and back again or from FLASHING to OFF to ON.  NOTE: Zones 
which do not have Roboguards programmed in will not function. 

 
5.2 RED Tamper LED FLASHING  
(Tamper Detection Triggered) 

If a Roboguard is tampered with, a tamper detected signal will automatically 
be sent to the keypad, it will sound the speaker 10 times, permanently flash 
the red tamper LED and activate one of the output switches. To establish 
which Roboguard was tampered with and to reset the tamper detect LED you 
must do the following: 
 

1.

  Press and release the tamper button (tamper LED on,  keypad is now in 

tamper detected display mode) 

2.

  The zone LED for the Roboguard that has been tampered with will be solid 

(on). 

3.

  Press and release all solid (on) LED's so only the red tamper LED is left 

on. 

4.

 Press and release the tamper button (LED off) or do nothing as the keypad 

will time out and exit automatically. 

5. 

 You are back in the main display page. 

 

NOTE : The Tamper indication will only be sent once per zone unless the 
tamper indication is reset. 

 

5.3 RED Trouble LED FLASHING  
(Automatic battery and radio strength test) 

 

The trouble (auto-test) routine is very important. The Roboguard sends an 
‘auto-test’ radio signal to the keypad every 20 minutes. Should a guard fail to 
report in, the keypad will indicate this by flashing the red ‘trouble’ LED and 
activate an output switch. To establish which Roboguard is reporting the 
trouble condition and to reset the trouble detect LED you must do the 
following. 

 

NOTE: This alarm is indicative of potential communication problems 
which may be due to bad radio reception or battery problems. 

 

1.

  Press and release the trouble button (trouble LED on, keypad is now in 

trouble condition display mode) 

2.

  The zone LED for the Roboguard that is “in trouble” will be solid (on). 

3.

  Press and release all solid (on) LED's so only the red trouble LED is on. 

4.

  Press and release the trouble button (LED off) or do nothing as the keypad 

will time out and exit automatically. 

5. 

 You are back in the main display page. 

 
 
 

Technical Details 

Dimensions: 

104 X 64 X 27 

Weight: 

100 g 

Current Consumption: 

+_ 25 mA 

Required receiver 

UHF 433.92 MHz 

Required Power Supply 

12V DC 

Colour: 

White 

Packing Contents 

keypad allen key 

keypad manual 

 

 

 

 

Trap International CC 

PO BOX 38113 

Point, 4069 

Durban 

South Africa 

 

[email protected] 

www.roboguard.co.za

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Roboguard keypad is a wired/fixed 4 + 2 zone decoder 

panel specifically designed to interface Roboguards and 

remotes to other systems or function as a complete 

system on its own. 

 