background image

 

 

 

 

Page 22 

Rev.0.0 

 

CineMonitor

HD

3DView evolution

 

Jan 4th 2010 

 

ZOOM 

Displays the HD picture in full resolution mode (pixel to pixel). 
Depending of the input format, the magnification ratio can be different. 
 
Displays the SD picture in full screen. In this case there is an important 
magnification ratio applied to the original picture, the resultant picture includes 
created pixels and lines and cannot be considered as a proof. In this mode the 
waveform will be superimposed to the picture. 

Arrows & Rotating knob 

In zoom mode arrows move the picture on Top/Bottom, Left/Right positions; Fine 
adjustment can be made by rotating the rotating knob. 
 
A long push on the ZOOM pad centers the picture, the next push sends back to 
the full picture display. 
 
During the zoom mode a pictogram is displayed in the right side of the tool zone.  
This pictogram indicates the relative position of the magnified zone in the original 
picture. 

 

ASPECT RATIO 

Allows the change of aspect ratio between: 
1.33:1  4/3 

SD only 

1.78:1  16/9 

HD & SD 

2.40:1   

HD & SD 

 

Summary of Contents for CineMonitorHD103DView evolution

Page 1: ...Rev 0 0 Jan 4th 2010 Doc ref CineMonitorHD3DView evolution Operator Manual cev fr ...

Page 2: ......

Page 3: ...Page 3 Rev 0 0 CineMonitorHD3DView evolution Jan 4th 2010 Figure 3 CineMonitorHD3DView6 back SDI Only ...

Page 4: ...3DView evolution 12 HD 3DView Monitor CineMonitorHD15 3DView evolution 15 HD 3DView Monitor If the physical electrical and optical characteristics of the products are different the user interface is the same Several configurations are optionally available for this family of products There is the choice at the order between several input boards which gives different functionalities described in thi...

Page 5: ...wer Requirements 13 OPERATION 14 Start Up Power 14 Using the direct access functions 14 F1 F4 14 Using the menus 15 Direct functions description 16 ENERGY MODE 16 MARKERS 16 Rotating knob 17 Measure Waveform Vectorscope Histogram 18 Rotating knob 20 Considerations about the use of measurement tools in 3DView mode 21 1 ZOOM 22 Arrows Rotating knob 22 ASPECT RATIO 22 USER 23 INPUT 25 ADJUST 26 MENU ...

Page 6: ...SORIN S MARKER ON OFF 36 BLACK LIMITS ON OFF 36 MEASUREMENT 37 SIGNAL ANALYSIS 37 OVEREXPOSURE ON OFF 37 SORIN S MARKER ON OFF 37 BLACK LIMITS ON OFF 37 1 LINE 37 12 LINES 37 ALL LINES 37 Background INTENSITY 37 SPOT INTENSITY 37 RETICULE INTENSITY 37 TALLY 38 NORMAL 39 HORIZONTAL FLIP 39 VERTICAL FLIP 39 PICTURE REVERSE 40 AUTO REVERSE 40 AUTO FLIP VERTICAL ONLY 40 3D 41 GRID 41 MODE 42 COLORS 42...

Page 7: ...TION 45 EXIT TEMPO 45 LED DIMMER 46 MEMORY 46 MEM 1 MEM 4 46 SAVE 46 RECALL 46 PRESET 46 PRESET ALL INPUTS 46 PRESET SELECTED INPUT 46 SERVICE MAINTENANCE 47 General 47 Useful tips 47 CLEANING 47 FULL RESET 47 Software and Firmware 48 Calibration 48 Product Return 48 ACCESSORIES 49 SPECIFICATIONS 51 CONNECTORS 53 TRANSVIDEO EQUIPMENT LIMITED WARRANTY 54 ...

Page 8: ...its software or any portion of them may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under the law CAUTION Warranty is void is the product is opened The unit contains electrostatic sensitive devices which can be damaged or destroyed if you touch them Refer to the standard ESD procedures before disassembly of the component Very high voltage are...

Page 9: ...Page 11 Rev 0 0 CineMonitorHD3DView evolution Jan 4th 2010 Product Overview Front Panel Controls and Indicators Rear Panel Controls and Connectors ...

Page 10: ...or secured professional use A slide with a 20 nut is delivered as standard equipment with the product This slide is fixed on the bottom of the monitor One or several optional slides can be attached to the sides back or top of the monitor 2 x M4 screws attach the slides Several TRANSVIDEO s accessories can be fixed in these positions this mounting system is generic for Transvideo since 1990 One squ...

Page 11: ...remely wide from 10 to 36 V DC except specified differently The power consumption slightly varies with the input voltage the operating temperature and the configuration of the product The power supply is protected against reverse polarity Over voltage may cause severe damages to the equipment For safety of use the CineMonitorHD3DView family feature a galvanic insulation of the DC input Do not conn...

Page 12: ... functionalities One long press more than 2 seconds on the pad allows access to the optional functionalities for the related function if any The rotating knob is a rotary encoder with a push function it is used to access and navigate in the menus adjust some parameter values validate and exit functions by pushing it A short push when on EXIT exits of the current menu to the previous level if any a...

Page 13: ...tating knob allows to access to the function sub menu Exit of the menu by selecting EXIT or by automatic temporization temporization can be adjusted in the TECHNICAL Menu Some feature described in this manual could be optional If your monitor do not show the feature described in this manual please check first if you bough the described option You can contact your distributor to upgrade your produc...

Page 14: ...served Allows having a reduced power mode between two takes F1 D56 F2 D65 F3 MANUAL Adjustable in MENU COLORIMETRY It is necessary to wait a few seconds after pressing the pad before loading of the correct lookup table MARKERS Displays the markers selected with F1 F4 Not active when the ZOOM or FORMAT 2 40 1 are selected This menu is contextual some functions can be unavailable depending of the in...

Page 15: ... 3D GRID or during the selection and call of the function through the MARKER direct access pad Rotating knob To adjust the offset of the 3D Grid when pushing shortly on MARKER and with grid selected The offset of the grid or horizontal positioning is adjustable of plus or minus half of the value of the grid By pressing more than 3 seconds the MARKER pad when the grid is displayed it is possible to...

Page 16: ...rt can be configured in MENU TOOLS LIMITS the same limits are used for the waveform monitor and the histogram representation Setting these limits is useful to have a visual alert on the waveform and histogram representation of the video signal if there is a risk of overexposure or of loss of black details F1 WAVEform F2 HISTOgram F3 VECTORscope Selecting F1 WAVE gives access to an other sub menu F...

Page 17: ...vailable modes Y R G B Y G B R R G B G B R Y Cr Cr F3 FRAME Displays Y R G or B in frame mode also named sweep mode The content of one frame picture is displayed Selecting F2 HISTOGRAM displays directly the representation F4 Return to the previous menu Selecting F3 VECTOR displays directly the representation ...

Page 18: ...3DView evolution Jan 4th 2010 Rotating knob When a measurement tool is displayed Pressing the WFM pad gives the possibility to adjust the representation by using the rotating knob Histogram Adjustment of the scale of the histogram ...

Page 19: ...torscope To identify clearly the source each spot uses a specific color The colors used are the same as those selected for the Anaglyph Monochrome mode The selection of the color is done in MENU 3D i e Using the HISTOGRAM with RED CYAN colors will display input 1 in RED and input 2 in CYAN The common values of the HISTOGRAM will be displayed in white the differences in BLUE or CYAN i e Using the H...

Page 20: ...d as a proof In this mode the waveform will be superimposed to the picture Arrows Rotating knob In zoom mode arrows move the picture on Top Bottom Left Right positions Fine adjustment can be made by rotating the rotating knob A long push on the ZOOM pad centers the picture the next push sends back to the full picture display During the zoom mode a pictogram is displayed in the right side of the to...

Page 21: ... Activates through the USER control the FOCUS HELPER function as programmed in MENU TOOLS FOCUS HELPER F3 EXPO Access to the OverExposure Control as configured in MENU TOOLS LIMITS F4 Jump to next page Page 2 F1 MEM Access to the Memory menu F2 Horizon F3 ZONE Allows to adjust the acquisition zone for the waveform and vectorscope Active when 1 line or 12 lines are selected F4 Jump to previous page...

Page 22: ...Page 24 Rev 0 0 CineMonitorHD3DView evolution Jan 4th 2010 b FOCUS c EXPO d Nothing The horizon is optional if the horizon is not implemented this menu will not appear ...

Page 23: ...eMonitorHD 3D View F1 SDI 1 F2 SDI 2 F3 3D View Pressing F1 F4 activates or not the selected input An active input appears in orange an inactive in white An inactivated input cannot be selected by the INPUT Attention To use the 3D View mode the cameras must be genlocked The CineMonitorHD 3DView gives the 3D functions with the following formats 1080i PsF 720p The 3D functions are not available with...

Page 24: ...ating the rotating knob Validate by pushing the rotating knob Important The settings are different for each input All settings are stored in setup memories There is one memory per input That means you can setup the ACCessory input differently of the SDI input It is useful with some specific digital cameras offering a viewfinder menu and a HD SDI preview output ...

Page 25: ...ignal Black to White level from 100 to 100 around of the nominal position SATURATION Setup the color saturation of the signal from 100 to 100 around of the nominal position BLUE CHECK Sets the monitor in BLUE ONLY mode This mode is used to calibrate the monitor with an incident color bar COLORIMETRY MANUAL Allows the manual adjustment of RGB gain from 0 to 2 nominal 1 00 and offset of the black 12...

Page 26: ... Vc represents the displayed signal and Vs is the incident signal The correction is applied with a simulated response of CRT GAMMA ADJUST Allows continuous adjustment 0 3 γ 2 5 The indicated value is for the corrected signal and do not indicate the monitor s gamma STANDARD 0 45 Set the monitor to reproduce a signal corrected by a γ of 0 45 Use in LINEAR To use the monitor with a linear signal non ...

Page 27: ...on TOOLS The tools make the richness of the CineMonitorHD3DView evolution AUDIO Displays the SDI embedded audio presence and a bargraph showing one audio pair on the 8 possible pairs AUDIO ON OFF Activates or deactivates the function CHANNEL PAIR X Selection of the pair displayed on the bargraph with the rotating knob POSITION Allows placing the tool in different position of the screen by using ar...

Page 28: ...deactivates the function ATC AUTO LTC VITC1 VITC2 Selection of the displayed VITC in AUTO mode the first time code present is displayed 1 LTC 2 VITC1 3 VITC2 POSITION Allows placing the tool in different position of the screen by using arrows and the rotating knob when USER is selected in the menu DEFAULT replaces the tool at the factory preset ...

Page 29: ...e COOKE 5 is able to light the focus and iris scales on the operator and or the assistant side Selection of the lighted zones OPERATOR ASSISTANT or ASSISTANT ONLY This function is available only if a COOKE 5 lens is detected BRIGHTNESS Adjust the brightness of the LEDs on a COOKE 5 lens This function is available only if a COOKE 5 lens is detected UNIT Selection of METRIC or IMPERIAL FILM Selectio...

Page 30: ...ress long time USER then set the function with F1 F4 COLOR Selection of the in focus zone color Red Green Blue Yellow Magenta Cyan Black or White LEVEL Adjustment of the selectivity of the filter OFF 1 to 5 5 gives the highest effect FRAMELINE This option allows displaying one locating cross and up to 3 programmable frames with or without center marker and a matting generator The menu shows differ...

Page 31: ...he center of the screen V SIZE Size of the frame bottom part is moving H SIZE Size of the frame right part is moving V POS Vertical position of the frame H POS Horizontal position of the frame V ZOOM Vertical homothetic modification of the frame H ZOOM Horizontal homothetic modification of the frame FRAME 2 FRAME 3 SEND ALL TO CENTER Send all frames to the center of the screen BCKGND COLOR Matting...

Page 32: ...ectronic bubble php NORMAL REVERSE Toggles the action of the horizon normal or reversed SENSITIVITY Adjusts the sensitivity of the virtual horizon True X2 X4 X8 X16 STYLE Allows to display or not the Horizon on the monitor Selects the style of the virtual horizon 6 different models Selects the presence or not of the horizon 0 CAL Set the horizon to 0 A temporization of 5 seconds allows stabilizing...

Page 33: ...imited by the MAX LEVEL setting All information over the limit will be displayed in orange on the waveform and the overexposed zone on the picture if the overexposure control is activated Default value 100 BLACK CLIPPING Set up the lower clipping level Black on the waveform Adjustment goes from 7 IRE to 35 IRE The lower value is limited by the MIN LEVEL setting All information below the limit will...

Page 34: ...k the exposure on skin tone The Sorin s marker is used to see all light equivalent zones i e to see the 0 stop zone of the picture OVEREXPOSURE ON OFF Switch ON or OFF the overexposure control The MAX LEVEL and the WHITE CLIP are displayed in false colors when activated SORIN S MARKER ON OFF Switch ON or OFF the Sorin s Marker The Sorin s area is displayed in false colors when activated BLACK LIMI...

Page 35: ...Switch ON or OFF the Sorin s Marker zoning on the measurement tools BLACK LIMITS ON OFF Switch ON or OFF the black limits zoning on the measurement tools 1 LINE Displays the measurement of one line selected with the rotating knob 12 LINES Displays the measurement of a group of 12 lines the first line is selected with the rotating knob ALL LINES Displays the measurement of the whole picture Backgro...

Page 36: ...connector J002 The menu shows different levels ACTIVE LOW HIGH Sets the state for TALLY ON LED ON OFF Activates deactivates the TALLY LED on the front panel TALLY BLINKING FIX Sets the active mode in TALLY ON STYLE Selects the style of the TALLY including the TALLY FRAME which is active on FRAME3 of the FRAMELINE The FRAMELINE option must be installed to use this mode ...

Page 37: ...Page 39 Rev 0 0 CineMonitorHD3DView evolution Jan 4th 2010 PICTURE FX NORMAL Restores the standard display HORIZONTAL FLIP Returns the picture horizontally VERTICAL FLIP Returns the picture vertically ...

Page 38: ... 2010 PICTURE REVERSE Returns the picture horizontally and vertically AUTO REVERSE Returns the picture automatically if the monitor is up side down AUTO FLIP VERTICAL ONLY Returns the picture automatically vertical axis only if the monitor is up side down ...

Page 39: ...d WIDTH Adjusts the separation between the vertical lines from 6 to 123 pixels The number of pixels is indicated on the incident picture not on the screen except when in ZOOM mode OFFSET Shifts the grid left or right of half of the WIDTH value COLOR Sets the color of the grid AREA Allows to clear the center of the grid in order to see the only the picture From 100 where the picture is fully covere...

Page 40: ...The pictures are interleaved To visualize the 3D effect it is necessary to use specific glasses The colors used in this mode depend of the settings of COLORS MONOCHROME The left camera SDI 1 and right camera SDI 2 are displayed in monochrome The colors used in this mode depend of the settings of COLORS This mode is useful to visualize the fringes between the 2 pictures COLOR The left camera SDI 1 ...

Page 41: ...IP The FLOP is a horizontal inversion of the picture mirror effect A push then a rotation of the knob activates or deactivates the FLIP of the left camera SDI1 right camera SDI2 or both cameras SDI1 SDI2 A push validates the choice It is possible to activate simultaneously the FLIP and the FLOP HORIZ SHIFT Turning the blue knob when the line is selected allows shifting the SDI2 picture Attention t...

Page 42: ... this time in Film Night Vision systems B W Displays the picture with 256 gray levels TINT and SATURATION are not working in this mode TECHNICAL CVBS STD SELECT Setting of the video composite standard AUTO DETECT Default value PAL BGHID NTSC 3 58 With some color video assist unit it may appears that the picture will be displayed in black and white in this case please select the appropriate standar...

Page 43: ...the voltage present on the power connector VOLTAGE ALARM LEVEL Sets the threshold voltage from 10VDC to 36VDC Under this voltage an alert can be displayed on screen VOLTAGE ALARM DISPLAY Activates VOLTAGE ALARM When activated the battery pictogram is displayed in red if the voltage of the power supply goes under the threshold setting POSITION Allows placing the tool in different position of the sc...

Page 44: ...t up in the memory All configuration except INPUT SEL is stored in the memory including Picture settings Tools settings Framing options RECALL Recall the settings stored in the memory The standard settings a factory loaded in this memory they will be replaced at the first SAVE from the user PRESET Set the default values in the setting registers PRESET does not erase the user presets PRESET ALL INP...

Page 45: ...ing Do not use abrasive or acid cleaners The microfiber cloth delivered with the CineMonitorHD3DView is strongly recommended to clean the glass Remove dust and particles of the glass before using the cloth No liquid is normally necessary If there is some dirt on the screen it is possible to remove it with clean warm water The microfiber cloth collects grease particle in its structure It is necessa...

Page 46: ...o perform the calibration you need to send the product s to the factory Product Return For technical operation you can return the product to the factory Previously you have to ask for a RAN Return Authorization Number Please provide the following information Product type Model Serial Number Purpose of the return You can contact us by Email service transvideo fr Fax 33 2 3260 1479 Phone 33 2 3232 2...

Page 47: ...0131 Firmly secures the CineMonitorHD3DView on a Spigot 3D SWING ARM Strong with Clamp for slide P N 918TS0148 Includes a Clamp for slide adapted on a 3D SwingArm reinforced for the CineMonitorHD3DView a 3 8 16 thread allows to fix the system to the camera adapters exist for 20 and metric Ikegami cameras Cardon Handle P N 918TS0151 This carbon handle fits on the Shoulder strap pins Shoulder strap ...

Page 48: ...ta or Porta Brace shoulder straps Light Hood 6 P N 918TS0161 8 P N 918TS0150 Light Lexan hood to use on Steadicam applications Battery Back P N 918TS0137 Standard version with V mount Available with PAG ANTON BAUER or NP1 on request Micro fiber cloth P N 918TS0092 Recommended cleaning cloth for the front glass Power Supply AL24 P N 918TS0040 For CineMonitorHD3DView 6 6SBL 8 15 Studio ...

Page 49: ...d SD standards NTSC M NTSC J NTSC 443 PAL M PAL BG SECAM PAL N Display mode Color Picture resolution Depends of the standard Storage temperature 40 C 80 C C F Operating temperature 20 C 55 C C F Display type AMLCD Color calibration D65 ITU R BT 709 5 D56 Color space Rec ITU R BT 709 5 Latency Less than 1 frame in 1080 i and PsF SD Less than 1 image in 720 and 1080 p ...

Page 50: ... h7 20 Centimeter Inches Weight 1680 3 7 Grams Lbs Power 10 36 17 5 Volts DC watts Brightness 450 NITs Contrast ratio 500 1 Sight angle 85 H V Specific CineMonitorHD3DView12 SB Parameter Value Unit Dimensions d68 x w298 x h285 d2 67 x w11 7 x h11 2 Centimeter Inches Weight 3700 8 1 Grams Lbs Power 11 36 32 Volts DC watts Brightness 1000 NITs Contrast ratio 500 1 Sight angle 85 H 70 80V Specific Ci...

Page 51: ...2 10 to 36 IN OUT 3 Y CVBS2 G 4 GND VIDEO 5 Pr R 6 Pb B 7 Run 8 GND Run Mating plug LEMO8 FGG1B308CLAD62 GPI CONNECTOR J0002 Sets the function attached to each remote input on J002 The default setup is J002 1 TALLY tally active when the contact is established J002 2 ZOOM change of state with a temporary contact J002 3 INPUT SELECT change of input with a temporary contact J002 4 HORIZON 0 LEVEL cal...

Page 52: ...Rev 0 0 Jan 4th 2010 Doc ref TRANSVIDEO S A Zone Industrielle F 27135 Verneuil sur Avre Tel 33 2 3232 2761 Fax 33 2 32 601479 Email info transvideo fr http transvideo fr http transvideointl com ...

Reviews: