background image

  After binding the app, back to the beginning page and click “Blood Pressure” to search 
  your test information.

Search your test information
 

BEFORE YOU START

Bluetooth Module No.: 

LS51802

RF Frequency Range:

 2402 MHz to 2480 MHz

Output Power Range: 

”G%P

Supply Voltage: 

1.8-3.6 V

Transmitting Distance: 

10 meters

CAUTION

Interference may occur in the vicinity of equipment marked with the following symbol      . And TMB-2085 may 
interfering vicinity electrical equipment.
Sensitive people, including pregnant women pre-eclamptic and those who implanted medical electronic instruments, 
should avoid using the unit whenever possible.
Keep the monitor at least 20 centimeters away from the human body (especially the head) when the data after  
transmission is proceeding measurement.
To enable the data transmission function, this product should be paired to Bluetooth end at 2.4 GHz. 

How to mitigate  possible interference?

1.The range between the device and BT end should be reasonably close, from 1 meter to 10 meters. Please ensure no 
obstacles between the device and BT end so as to obtain quality connection and to lower the RF output range.
 2. To avoid interference, other electronic devices (particularly those with wireless transmission / Transmitter) should be 
kept at least 1 meter away from the monitor.     

List of compatible devices

For iOS devices:
The operating system must be iOS 11.0 or more.
For Android devices
The operating system must be Android 8.0 or more

BEFORE YOU START

Summary of Contents for TMB-2085

Page 1: ...istrict Zhongshan 528437 Guangdong China Thank you for selecting Transtek Blood Pressure Monitor Please read the user manual carefully and thoroughly so as to ensure the safe usage of this product Kee...

Page 2: ...What are systolic pressure and diastolic pressure What is the standard blood pressure classification Irregular heartbeat detector Why does my blood pressure fluctuate throughout the day Why do I get...

Page 3: ...e design provides you with two years of reliable service Readings taken by this blood pressure monitor TMB 2085 is equivalent to those obtained by a trained observer using the cuff and stethoscope aus...

Page 4: ...a physician for treatment advice If you are taking medication consult your physician to determine the most appropriate time to measure your blood pressure Never change a prescribed medication without...

Page 5: ...ipment is in use The patient is an intended operator Please dispose of ACCESSORIES detachable parts and the ME EQUIPMENTaccording to the local guidelines CAUTION The patient can measure data and chang...

Page 6: ...nd put into service in accordance with the information provided in the ACCOMPANYING DOCUMENTS Wireless communications equipment such as wireless home network devices mobile phones cordless telephones...

Page 7: ...s transmitting Memory Query Indicate it is in the memory mode and which group of memory it is Average value The average value of the latest three groups bood pressure value The bluetooth icon blinks w...

Page 8: ...U START CUFF Type BF applied part BATTERY COMPARTMENT Slide off the battery cover Replace the battery cover Install the batteries as indicated in the battery compartment Always use the correct battery...

Page 9: ...Batteries may explode or leak Remove batteries if the device is not likely to be used for some time Worn batteries are harmful to the environment Do not dispose with daily garbage Remove the old batte...

Page 10: ...ss the START STOP button to confirm the entry The screen will then show a blinking number representing the MONTH 4 Repeat steps 2 and 3 to set the MONTH and DAY 6 Repeat steps 2 and 3 to set the UNIT...

Page 11: ...measurement please set your desired user ID 1 When the blood pressure monitor is off hold press START STOP button and then the user ID shows Then press MEM button to switch the user ID between user A...

Page 12: ...Pair Up Download the Transtek Health app from APP Store or Google Play Install the APP and register an account Click click My setting choose the device and then bind the device and app BEFORE YOU STA...

Page 13: ...or at least 20 centimeters away from the human body especially the head when the data after transmission is proceeding measurement To enable the data transmission function this product should be paire...

Page 14: ...f the right atrium of the heart Before starting measurement please sit comfortably with legs uncrossed feet flat on the floor back and wrist supported Rest for 5 minutes before measuring Wait at least...

Page 15: ...king and the data will start transmitting 4 If the data transmition fails the monitor will turn off automatically 3 If the data transmits successful the symbol and symblo will disappear and then the m...

Page 16: ...for 3 seconds it will display dEL ALL User ID 2 Press MEM button to confirm deleting the LCD will display dEL dOnE User ID and then turn off The most recent record 1 is shown first Each new measureme...

Page 17: ...our fingers In a very cold environment When you want to discharge urine Maintenance To obtain the best performance please follow the instructions below Avoid shaking and collision Avoid immersing it i...

Page 18: ...e Irregular Heartbeat Detector When ventricles contract and pump blood out of the heart blood pressure reaches its maximum value the highest pressure in the cycle is known as systolic pressure When th...

Page 19: ...ce Relax yourself for 4 5 minutes until you calm down Is the result the same if measuring on the right wrist It is ok for both wrists but there will be some different results for different people We s...

Page 20: ...water vapour partial pressure greater than 50 hPa An atmospheric pressure range of 700 hPa to 1060 hPa Temperature 20 C to 60 C UHODWLYH KXPLGLW UDQJH RI QRQ FRQGHQVLQJ at a water vapour pressure up t...

Page 21: ...user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tes...

Page 22: ...asurement type EN 1060 4 2004 Non invasive sphygmomanometers Part 4 Test procedures to determine the overall system accuracy of automated non invasive sphygmomanometers EN 60601 1 6 2010 A1 2015 IEC 6...

Page 23: ...ecreased electromagnetic immunity of this equipment and result in improper operation Warning Portable RF communications equipment including peripherals such as antenna cables and external antennas sho...

Page 24: ...30 A m 50Hz 60Hz Power frequency magnetic field IEC 61000 4 8 Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 Electrical fast transient burst IEC 61...

Page 25: ...modulation b 18Hz 1 8 450 430 470 GMRS 460 FRS 460 FM c 5kHz deviation 1kHz sine 2 0 3 28 710 704 787 745 780 LTE Band 13 17 Pulse modulation b 217Hz 0 2 0 3 9 810 870 930 800 960 GSM 800 900 TETRA 80...