ABOUT BLOOD PRESSURE
INFORMATION FOR USER
Please calibrate the blood pressure monitor in specific institute once
every two years to ensure the precise measurement. In order to get the
best performance, please follow the instructions below for storage.
Maintenance
Only a physician can tell your normal BP range.
Please contact a physician if your measuring
result falls out of the range. Please note that
only a physician can tell whether your blood
pressure value has reached a dangerous point.
What are systolic pressure and diastolic pressure?
press
artery
vein
blood discharging
Systolic
relax
blood entering
Diastolic
When ventricles contract and pump blood out of the
heart, the blood pressure reaches its maximum value
in the cycle, which is called systolic pressure. When
the ventricles relax, the blood pressure reaches its
minimum value in the cycle, which is called diastolic
pressure.
What is the standard blood pressure classification?
The blood pressure classification published by
World Health Organization (WHO) and International
Society of Hypertension (ISH) in 1999 is as follows:
Irregular Heartbeat Detector
CAUTION
The appearance of the IHB icon indicates that a pulse irregularity consistent with an
irregular heart-beat was detected during measurement. Usually this is NOT a cause for
concern. However, if the symbol appears often, we recommend you seek medical advice.
Please note that the device does not replace a cardiac examination, but serves to detect
pulse irregularities at an early stage.
CAUTION
Put in a dry place and avoid the sunshine
Avoid intense shaking
and collisions
Using wet cloths to remove dirt
Avoid touching water,
clean it with a dry cloth in case.
temperature environment
Do not attempt to clean the reusable cuff
with water and never immerse the cuff in
water.
SYS
DIA
<120
<80
120-129
80-84
130-139
85-89
140-159
90-99
160-179
100-109
≥180
≥110
Level
Blood
Pressure (mm Hg)
Optimal
Normal
High-normal
Mild
Moderate
Severe
An irregular heartbeat is detected when a heartbeat rhythm varies while the device is measuring
systolic pressure and diastolic pressure. During each measurement, blood pressure monitor will
keep a record of all the pulse intervals and calculate the average value of them. If there are two or
more pulse intervals , the difference between each interval and the average is more than the
average value of ±25% , or there are four or more pulse intervals ,the difference between each
interval and the average is more than the average value of ±15%, then the irregular heartbeat
symbol will appear on the display with the measurement result.
Avoid dusty and unstable