INTRODUCTION……………………………………………………………………………………2

General Description

Safety Information

LCD Display Signal

Monitor Components

 

BEFORE YOU START…………………………………………………………………………......6

The Choice of Power Supply

Installing and Replacing the Batteries

Setting Date, Time and Measurement Unit

MEASUREMENT…………………………………………………………………………………...9

Tie the Cuff

Start the  Measurement

DATA MANAGEMENT………………………………………………………………………….....11

Recall the Records

Delete the Records

INFORMATION FOR USER……………………………………………………………………...13

Tips for measurement

Maintenances

ABOUT BLOOD PRESSURE…………………………………………………………………….15

What are systolic pressure and diastolic pressure?

What is the standard blood pressure classification?

Why does my blood pressure fluctuate throughout the day?

Why do I get a different blood pressure at home compared to the hospital?

Is the result the same if measuring on the right arm?

TROUBLESHOOTING…………………………………………………………………………….17

SPECIFICATIONS…………………………………………………………………………………18

AUTHORIZED COMPONENT ………………………………………………………………......19

CONTACT INFORMATION…………………………………………………………………….....19

COMPLIED EUROPEAN STANDARDS LIST………………………………………………….20

EMC GUIDANCE……………………………………………………………………………….....21

Table of Contents

1

CATALOGUE

CATALOGUE

Summary of Contents for TMB-1018-A

Page 1: ...r selecting TRANSTEK Blood Pressure Monitor TMB 1018 A Please keep this manual well in order to reference in future Arm Type Version 1 0 EC REP Guangdong Transtek Medical Electronics Co Ltd Zone A No...

Page 2: ...ON FOR USER 13 Tips for measurement Maintenances ABOUT BLOOD PRESSURE 15 What are systolic pressure and diastolic pressure What is the standard blood pressure classification Why does my blood pressure...

Page 3: ...deflate Should the cuff not deflate when pressures exceeds 40 kPa 300 mmHg detach the cuff from the arm and press the START STOP button to stop inflation The equipment is not AP APG equipment and not...

Page 4: ...ure 1kPa 7 5mmHg Low battery Batteries are low and need to be replaced Shocking reminding Shocking will result in inaccurate Average The average of blood pressure Recalling The records will be showed...

Page 5: ...ery cover Install the batteries by matching the correct polarity as shown Replace the cover 1 Battery powered mode 6VDC 4 AAA batteries 2 AC adaptor powered mode 6V 1A Please only use the recommended...

Page 6: ...he cuff should be snug but not too tight You should be able to insert one finger between the cuff and your arm 3 Sit comfortably with your tested arm resting on a flat surface 2 3cm 4 Repeat steps 2 a...

Page 7: ...st CAUTION The order of the record date time will display alternately 1 When the monitor is off press the START STOP to turn on the monitor and it will finish the whole measurement Adjust the zero LCD...

Page 8: ...3 If you don t want to delete the records press START STOP to escape If you did not get the correct measurement you can delete all results by following steps below Delete the Records 4 If there is no...

Page 9: ...classification The blood pressure classification published by World Health Organization WHO and International Society of Hypertension ISH in 1999 is as follows Irregular Heartbeat Detector CAUTION Th...

Page 10: ...fer to the warranty for contact information and return instructions E21 shows The treatment of the measurement failed Relax for a moment and then measure again AC adaptor is inserted incorrectly Inser...

Page 11: ...00 240V 50 60Hz 400mA Output 6V 1A Type UE08WCP 060100SPA Conforms to UL certificate Contact Information For more information about our products please visit www transtek cn you can get customer servi...

Page 12: ...ablishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Risk management Labeling User manual General Requirements for...

Page 13: ...G Guidance and manufacturer s declaration electromagnetic immunity IMMUNITY test Not applicable 3 V m Compliance level IEC 60601 TEST LEVEL Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 V m 8...

Page 14: ...the device as recommended below according to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmit...