background image

User Manual

Blood Pressure Monitor

TMB-1014-BT

To use the monitor correctly and safely, please read the manual 
thoroughly.

Thank you very much for selecting TRANSTEK Blood Pressure Monitor 
TMB-1014-BT.

Please well keep this manual in order to reference in future.

Zhongshan Transtek Electronics Co., Ltd
Jin’an Road, Minzhong, Zhongshan 528441, Guangdong, China

Wrist Type

Version:1.0

Summary of Contents for TMB-1014-BT

Page 1: ...please read the manual thoroughly Thank you very much for selecting TRANSTEK Blood Pressure Monitor TMB 1014 BT Please well keep this manual in order to reference in future Zhongshan Transtek Electron...

Page 2: ...matically deflate Should the cuff not deflate when pressures exceeds 40 kPa 300 mmHg detach the cuff from the wrist and press the START STOP button to stop inflation To avoid measurement errors carefu...

Page 3: ...gh pressure result Diastolic blood pressure Low pressure result Pulse Pulse minute mmHg Measurement unit the blood pressure Time Currently time Low battery Batteries are low and need to be replaced Er...

Page 4: ...mory In sure the lock key is glided to the unlock mode year 2010 2050 time 24 H Remove batteries if the device is not likely to be used for some time The old battery is harmful to the environment so p...

Page 5: ...column will remind searching for device 3 Long press the START button after power off the blood pressure monitor it ll show moving o 4 At this moment the discovered device column of mobile will displ...

Page 6: ...blood pressure monitor show it means matching successfully When it display E1 it indicates matching unsuccessfully 7 If matching successfully it will show the lately measuring record on the receive d...

Page 7: ...atically Display and save the results automatically Start the Measurement 4 Press the START STOP to power off otherwise it will turn off automatically within 1 minute 2 After measuring it ll display t...

Page 8: ...3 and so on and the last record 60 is dropped from the list CAUTION UP DOWN MEM SET MEM SET If you did not get the correct measurement you can delete all results by following below steps Deleting a me...

Page 9: ...lision Using the wet clothing to remove the dirt Avoid touching water clean it with a dry cloth in case Avoid the dusty and unstable temperature environment Avoid washing the cuff Clean the cuff with...

Page 10: ...too loose If the cuff is tied on the wrist If you feel anxious pressured You had better take deep breath 2 3 times before beginning Advice adjust yourself for 4 5 minutes until you calm down ABOUT BLO...

Page 11: ...the products not operating as you think it should check here before arranging for servicing PROBLEM SYMPTOM CHECK THIS REMEDY No power Low batteries Error massage Display is dim or will not light up...

Page 12: ...ission CISPR 11 The TMB 1014 BT uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment The TM...

Page 13: ...location in a typical commercial or hospital environment 3A m Power frequency 50Hz magnetic field IEC 61000 4 8 Voltage dips short interruptions and voltage variations on power supply input lines IEC...

Page 14: ...equipment and the EQUIPMENT or SYSTEM for ME EQUIPMENT or ME SYSTEM that are not LIFE SUPPORTING Recommended separation distances between portable and mobile RF communica tions equipment and the ELE00...

Page 15: ...and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this...