background image

8

9

Start Measuring

Manage Your Health

With batteries correctly installed, press “UNIT” button in the back of the scale to select 

measurement unit. The default measurement unit is “kg”. You may press “UNIT” 

button to choose among kilogram, stone and pound.

Select Measurement Unit

With original SENSE ON patent technology, the scale 
will automatically switch on as you step on the platform 

barefooted. 

Stand still and keep full contact with the electrodes until 

the LCD stops blinking “BIA”.

When your scale is successfully paired with your iPhone and the Bluetooth is ON, 

it will process data transmission automatically. 
(

Please refer to Data Transmission for more details.

)

Daily Measurement

With the scale successfully pair-up with your 

iPhone, the measurement data will be automatically 

transmitted to your mobile via Bluetooth.

The symbol      will disappear after successful data 

transmission, and you may check your personal 

health data stored in your iPhone.

If the data transmission fails, the symbol      will 

remain. The pending measurement data will be 

temporarily kept in the scale and transmitted to your 

iPhone when next measurement is complete.

Data ready to transmit to

Data transmitting 

the App:

-If SUCCEED, the symbol 

disappears;

-If FAIL, the symbol 

remains.

Data Transmission

CAUTION

Interference may occur in the vicinity of equipment marked with the following symbol        . And 

the Analyzer may interfere vicinity electrical equipment.
To enable the data transmission function, this product should be paired to a Bluetooth end at 

2.4 GHz.

How to mitigate possible interference?

1. The range between the Analyzer and the Bluetooth end should be reasonably close, from 1 

meter to 10 meters. Please ensure no obstacles between the Analyzer and the Bluetooth end 

so as to obtain quality connection.

2. To avoid interference, other electronic devices (particularly those with Bluetooth transmission 

/ Transmitter) should be kept at least 1 meter away from the Analyzer. 

Bluetooth Module No.: 

AW8001

RF Frequency Range:

 2402MHz to 2480 MHZ

Output Power Range: 

4 dBm

Supply Voltage: 

3V to 3.6V

CAUTION

The normal measuring time  cannot over 1 minute.

After the measurement, please don’t stand on the scale for a long time.

Continous to use the scale for a long time, the surface temperature may exceed 41

℃,

this will cause burns.

Summary of Contents for LS203-B

Page 1: ...ina TEL 86 760 88282982 www transtek cn Contains FCC ID OU9AW8001 LS User Manual Glass Body Fat Analyzer LS203 B Please do read the user manual carefully and thoroughly so as to ensure the safe usage...

Page 2: ...rt Measuring Select Measurement Unit Daily Measurement Manage Your Health Data Transmission Troubleshooting Error Prompt When Measuring When Data Transmitting Specifications Maintenance Warranty FCC R...

Page 3: ...analysis BIA technology to estimate body fat total body water percentage bone mass and muscle mass in generally healthy adults 18 years of age or older It is intended for use in the home domestic sett...

Page 4: ...aline Batteries 1 5V each 3 User Manual Device Components LCD Display Electrode Battery Compartment UNIT and activation Button Electrode Stone Pound Bioelectrical Impedance Analysis Kilogram Data tran...

Page 5: ...batteries Please replace all four batteries in the same time Do NOT mix the old batteries with the new one Worn batteries are hazardous waste Do NOT dispose of them together with the household garbage...

Page 6: ...rarily kept in the scale and transmitted to your iPhone when next measurement is complete Data ready to transmit to Data transmitting the App If SUCCEED the symbol disappears If FAIL the symbol remain...

Page 7: ...feet to resume blood circulation and then measure again Cold body that may results in bad blood circulation When Measuring Problem Root Cause Solution Cold Electrodes Either your hands or your feet a...

Page 8: ...A size Alkaline Batteries Auto ON SENSE ON technology Auto OFF About 10 seconds while showing 0 0 About 15 seconds after the weight data is locked Accessories 1 Four AAA size Alkaline Batteries 2 User...

Page 9: ...ation FCC User Guide Information Radio Frequency Interface Requirements FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of...

Page 10: ...7 1 24 24 1 27 27 23 23 1 31 31 1 34 34 17 60 18 1 25 25 1 28 28 24 24 1 32 32 1 35 35 18 Low Normal High V High Low Normal High V High Woman Sportswoman Health Tips About Body Fat Gender Men Women Bo...

Page 11: ...on power supply input lines IEC 61000 4 11 Electrical fast transient burst IEC 61000 4 4 Surge IEC 61000 4 5 Table 4 Guidance and manufacture s declaration electromagnetic immunity for ME EQUIPMENT an...

Page 12: ...ed separation distances between portable and mobile RF communications equipment and the ME EQUIPMENT or ME SYSTEM for ME EQUIPMENT and ME SYSTEMS that are not LIFE SUPPORTING Recommended separation di...