TransTank FireGuard Operator'S Handbook Manual Download Page 3

1800  816  277

www.tti.com.au

3

Product HandBook

FireGuard

Disclaimer 

All information, illustrations, and specifications contained in this manual are based on the latest product 

information available at the time of this publication’s printing.  TransTank International (TTi) reserves the right 

to alter and substitute specifications and methods at any time, in line with our commitment to continuous 

improvement.

No patent liability is assumed with respect to the use of information contained within this manual.  While 

every precaution has been taken in the preparation of this manual, TTi assumes no responsibility for errors or 

omissions.

Thank you for purchasing a FireGuard™ Portable Fire Fighting Unit 

(FireGuard), which will provide many years of reliable service when 

operated and maintained in accordance with this manual.

TTi manufactures two FireGuard units, a 220 litre and 400 litre tank sizes, both fitted with a petrol driven 
pump.  This manual describes the operation, driving stability and maintenance procedures applicable to the 
unit.

All TTi FireGuard tanks are rotationally moulded from quality polyethylene, purpose designed and 
manufactured to high standards.  The FireGuard is a compact portable unit for the back of a utility or trailer 
and designed for firefighting, tree watering and washdown activities.

The FireGuard unit is supplied complete, tested and ready to go.  TTi recommends that only water be used 
in the FireGuard unit.  TTi warrants that the FireGuard has been designed and built for its intended purpose 
for dispensing water for activities such as firefighting, tree watering and washdown.

The owner is responsible to ensure that the equipment is operated in accordance with this manual, with 
Australian WorkSafe requirements, applicable road rules and local council regulations.  TTi is not liable for 
any loss, injury or death resulting from the failure to observe all safe working regulations as required by law.

Included with your FireGuard unit is the following documents:

• 

Operator’s Handbook (this manual, which includes the Warranty Registration Card)

• 

Honda Petrol engine manufacturer’s handbook

• 

Aussie Pumps manufacturer’s handbook

• 

Tank Quality Check Form. This is your verification that the unit has been quality checked, and verifies the 
serial number affixed to the unit.

 

Summary of Contents for FireGuard

Page 1: ...Operator s HandBook FireGuard w w w t t i c o m a u Manufacturer of The Safest Tanks in Motion...

Page 2: ...ions 7 Driving Stability 7 Operating Instructions 7 Before First Use 7 Filling the Tank 9 Pump Operation Procedure 9 FireGuard Operation 10 Risk Assessment 11 Maintenance 12 Periodic Checks 12 Mainten...

Page 3: ...nks are rotationally moulded from quality polyethylene purpose designed and manufactured to high standards The FireGuard is a compact portable unit for the back of a utility or trailer and designed fo...

Page 4: ...emicals 2 Only authorised and trained personnel are to operate this equipment Operators must have read and fully understood this manual before operating the FireGuard unit 3 Do not operate this equipm...

Page 5: ...an and legible and replaced if damaged 14 Any unauthorised modifications to this equipment may affect its function and create a serious safety risk Any unauthorised modifications will void any warrant...

Page 6: ...aterial polyethylene and are fully drainable Due to the rotational moulding process there may be a small variance in the overall dimensions of the tank therefore calibration markings should be used as...

Page 7: ...Stability The FireGuard unit is heavy when filled with water To maintain stability while operating this unit Ensure the vehicle s tyres are inflated to their correct pressure at all times Underinflate...

Page 8: ...tray If using tie down straps they must be rated to at least the total mass of the unit when filled with water There is one tie down recess across the 220L FireGuard tank refer to Figure 1 with two r...

Page 9: ...iller cap Pump Operation Procedure The FireGuard s petrol pump engine is started as follows refer to Figure 4 1 Turn the fuel lever to ON 2 If the engine is cold turn the choke lever to ON NOTE Ensure...

Page 10: ...reGuard Ensure the fire hose s nozzle in closed 4 Start the pump s engine referring to the Pump Operation Procedure above and adjust engine speed CAUTION To prevent damage do not operate the pump for...

Page 11: ...ling slips trips or falls Low Follow safe manual handling techniques don t lift on your own if 20kg bend knees keep back straight Use fire fighting unit As above loss of load heat cold noise exceed lo...

Page 12: ...eners and fittings are firmly secured tighten if necessary 3 Unwind the hose from its bracket fully to check that hose is in good order Pressurise the line and check operation of spray nozzle Rewind t...

Page 13: ...nd clean the engine s air filter 3 Check engine oil level top up as required Monthly Tasks The following tasks are to be undertaken each month or 20 operating hours whichever occurs first No Task Date...

Page 14: ...ne s air filter 3 Drain and flush the fuel tank 4 Replace the engine s fuel filter 5 Replace the spark plug Two Yearly tasks The following tasks are to be undertaken every 24 months or 500 operating h...

Page 15: ...aking service calls clean up time and transport charges 3 The use of non genuine parts on equipment supplied by TTi This will automatically negate any warranty How to Obtain Service Under this Warrant...

Page 16: ...i com au 1800 816 277 sales tti com au PO Box 137 Nathalia VIC 3638 Murray Valley Hwy Nathalia VIC 3638 Proudly Built By Signature Date Signature Date Quality Checked By Scan to view our PDF Handbook...

Reviews: