background image

Specifications

NOTE: 

MONITOR functions of UL325

 

(01) End of Line Resistor (10K )
(02) N.C. contact (Optional)

 

Depending on the monitoring system used by the gate motor, 
it may be necessary to use either the N.C. output or connect 
the included 10K resistor to the N.O. or N.C. output.

Please refer to the gate operator manual or the gate operator 
manufacturer for the preferred monitoring method.

Input Volt.   

 

12-30 VDC/AC 60 Hz (Non Polarity)

Current consumption   

100 mA

Tx LED Element    

 Infrared LED/Wave length 740 nm

Beam Spreading angle   

5˚ 

Contact Capacity    

30VDC/AC, 0.5A

Response Time    

10 msec

Delay Time of Relay  

10 msec

Sensing Range    

10 meters

LED Indicators:
Red LED Off: Beam aligned / Red LED On: Beam broken
Red LED flash: Beam alignment signal weak (Re-align)
Green LED on: Beam aligned proper

Additional Function  

Tamper switches

Wiring Connection   

Terminal block / Cable gland (IP-55)

IP 

 

  IP-55

Environment/Storage Temp   -13˚F to 140˚F / -31˚F to 176˚F

Dimension  

 

122 (L) x 61 (W) x 62 (D) mm

Cable wires  

 

2517 / 24AWG / 5~7 cores

Approvals  

 

UL325-2016 & CE

1

 

 

Reviews: